a) General Requirements:
1) Showers shall be required
when necessary at specified locations to protect employees whose work involves
exposure to poisonous, infectious or irritating material or to excessive dirt,
heat fumes or vapors or other materials or substances injurious to
health.
2) Shower facilities shall
be provided in conjunction with lockers or dressing room facilities, as
required by this Part.
3) Whenever
a shower is required under subsection (a)(1), where 6 or more women are
employed at any one time, a separate shower room shall be provided for their
use. Where at least one, but fewer than 6 women are employed and a separate
shower room is not provided, accommodation must be made to ensure privacy,
including a latch or lock on the door leading to the shower room.
b) Specifications:
1) Showers shall be provided with a spray
fixture connected to an ample supply and pressure of hot and cold water,
preferably mixed by a mixing valve.
2) Each shower room or compartment shall be
constructed of material impervious to moisture.
3) Each shower compartment shall be not less
than 32 inches in width and 32 inches in depth.
4) Shower floors shall be constructed of
non-slippery materials. Floor drains shall be provided in all shower baths and
shower rooms to remove waste water and facilitate cleaning. All junctions of
the curbing and the floor shall be sealed. The walls and partitions of shower
rooms shall be smooth and impervious to the height of splash.
5) An adequate supply of hot and cold running
water shall be provided for showering purposes. Facilities for heating water
shall be provided.
c) Camp Car Showering Facilities:
1) Camp cars
used to house employees shall include 2 showers within each sleeping
car.
2) Shower floors shall be
constructed of non-slippery materials. Floor drains shall be provided in all
shower baths and shower rooms to remove waste water and facilitate cleaning.
All junctions of the curbing and the floor shall be sealed. The walls and
partitions of shower rooms shall be smooth and impervious to the height of
splash.
3) An adequate supply of
hot and cold running water shall be provided for showering purposes. Facilities
for heating water shall be provided.
d) Camp Car Showers:
1) Unless otherwise provided by agreement
between a rail carrier and organized labor, body soap or other appropriate
cleansing agent convenient to the showers shall be provided.
2) Showers shall be provided with hot and
cold water feeding a common discharge line.
3) Unless otherwise provided by agreement
between a rail carrier and organized labor, employees who use showers shall be
provided with individual clean towels.
Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google
Privacy Policy and
Terms of Service apply.