a) All home units, at a minimum, must meet the requirements of this subsection (a).
1)
Home units must be able to be activated from:
A) a wireless remote; and
B) from the telephone, using a predetermined
number;
2) The wireless
remote activator must have:
A) a crystal or
Surface Acoustic Wave (SAW) resonator controlled transmitted frequency for
long-term reliability;
B) digital
encoding capability for at least 10 combinations;
C) a minimum transmission range of 175
feet;
D) an internal battery with a
minimum life of 5 years;
E) low
battery signal; and
F)
certification under 47 CFR
15.
3) The base unit or communicator unit must:
A) be an integrated unit that connects to the
individual's telephone via a modular jack which does not interfere with the
normal use of the telephone or be an integrated unit that connects to a stable
cellular network available to the individual's primary residence;
B) connect to a standard home electrical
outlet, as its power supply, by use of an Underwriter's Laboratory approved
plug;
C) be able to seize the
telephone line, even when a telephone in the dwelling is connected via a
modular jack and is off the hook, and dial the EHRS Center to transmit an
emergency signal;
D) the base unit
must have an easily identifiable "Ready" light to verify the unit is on-line
with the EHRS Center;
E) the base
unit must have an easily identifiable "confirmation" light to indicate that, if
activated, the EHRS Center has received the call;
F) disconnect and redial, until the call is
received at the EHRS Center, if an emergency call does not reach the EHRS
Center;
G) have a simple process by
which signals may be aborted, in the event an erroneous signal is
sent;
H) have a battery, which is
continuously charged while the unit is on, that will maintain a charge for at
least 12 hours in the event of an electrical power failure;
I) transmit a message to the EHRS Center
signifying maintenance of the unit is required in the event of base unit
battery failure; and
J) be
certified under 47 CFR
15 and
68.
b) All EHRS Center equipment, at a minimum, must:
1) be capable of automatically receiving
all signals and displaying and printing all messages sent from home
communicators connected to the EHRS system;
2) have an audible and visual alarm for the
notification of all incoming signals;
3) display and print the incoming message,
date, time, and Customer identification for each incoming signal;
4) have a battery back-up which will
automatically take over should there be a power outage, or a single circuit
failure. This battery back-up must supply sufficient power to operate the
entire system for a minimum of 8 hours in the event of an outage;
5) have totally separate and independent
primary and back-up receivers. If the primary receiver should fail, the system
must automatically transfer to the back-up receiver to ensure no interruption
in services;
6) monitor all
connected telephone lines and give an audible signal should one of the
connected telephone lines be out of service for a period of longer than one
minute;
7) be able to identify each
individual Customer account;
8)
perform self-diagnostic testing and monitoring to indicate the status of fault
conditions, which could interfere with receiving signals and monitoring
telephone connections such as power loss, telephone line outages, signals
received with no messages, nonoperating transmitters, etc.; and
9) be certified under
47 CFR
15 and
68.
Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.