Section 501.300 - Correctors

Current through Register Vol. 48, No. 38, September 20, 2024

a) A utility shall install all correctors in accordance with the recommendations of AGA Gas Measurement Manual, Electronic Corrector, Part No. 15 (May 1999), XQ9901.

b) A utility that installs an electronic or mechanical corrector shall verify the proper operation of the corrector at least every 60 months.

1) Verification temperatures are 32°F and 75°F/or flowing gas temperature with a tolerance of ± 2.5 °F.

2) Verification pressures are zero and flowing pressure with a tolerance of ± 1%.

c) A utility shall maintain the most recent 10 years of inspection records.

Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.