Illinois Administrative Code
Title 8 - AGRICULTURE AND ANIMALS
Part 215 - ANHYDROUS AMMONIA, LOW PRESSURE NITROGEN SOLUTIONS, EQUIPMENT, CONTAINERS, AND STORAGE FACILITIES
Subpart B - NITROGEN FERTILIZER SOLUTIONS
Section 215.245 - Transfer of Liquids
Universal Citation: 8 IL Admin Code ยง 215.245
Current through Register Vol. 48, No. 12, March 22, 2024
a) A competent attendant shall supervise the transfer of liquids from the time the connections are first made until they are disconnected.
b) Pumps shall be of a material suitable for use with the solution being handled and designed to withstand the working pressure.
c) Air compressors may be used for transfer of nitrogen fertilizer solutions.
1) The air compressor shall be protected with
a back flow check valve in the air line to prevent the flow of nitrogen
fertilizer solutions or vapor from the container into the air
compressor.
2) A relief valve large
enough to discharge the full capacity of the compressor shall be connected to
the discharge before any shutoff valve.
d) All storage installations shall be equipped with devices so as to minimize tampering while installation is unattended.
e) Containers shall be filled or used only upon authorization of owner or owner's agent.
Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.