Illinois Administrative Code
Title 8 - AGRICULTURE AND ANIMALS
Part 215 - ANHYDROUS AMMONIA, LOW PRESSURE NITROGEN SOLUTIONS, EQUIPMENT, CONTAINERS, AND STORAGE FACILITIES
Subpart A - ANHYDROUS AMMONIA, EQUIPMENT, CONTAINERS, AND STORAGE FACILITIES
Section 215.60 - Filling Densities

Universal Citation: 8 IL Admin Code ยง 215.60

Current through Register Vol. 48, No. 12, March 22, 2024

a) Filling density is limited to 85% capacity by volume at 60°F.

b) The filling densities for non-refrigerated containers shall not exceed the following:

1) Uninsulated aboveground 56%;

2) Insulated aboveground 57%.

c) US Department of Transportation containers shall be filled in accordance with 49 CFR 173.315(m)(5).

d) If containers are to be filled according to liquid level by any gauging method other than a fixed length dip tube gauge, each container shall have a thermometer well and thermometer so that the internal liquid temperature can be easily determined and the amount of liquid and vapor in the container corrected to a 60°F basis.

Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.