NUMBER OF BED-ROOMS

SEWAGE FLOW PER DAY (Gal.)

SEPTIC TANK SIZE (Gal.) No Garbage Grinder

RECIRCU-LATION TANK SIZE (Gal.)

AREA OF SAND FILTER (Sq. ft.)

RECOM-MENDED SIZED OF SAND FILTER

NUMBER OF UNDER-DRAINS

NUMBER OF DISTRI-BUTION PIPES

1

200

750

500

100

10' x 10'

1

3

2

400

750

500

133

11' x 12'

1

3

3

600

1,000

500

200

14' x 14'

1

4

4

800

1,250

500

266

16' x 17'

1

5

5

1,000

1,500

500

333

18' x 19'

2

6

6

1,200

1,750

500

400

20' x 20'

2

6

7

1,400

2,000

500

466

20' x 23'

2

6

8

1,500

2,250

500

500

20' x 25'

2

6

Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.