Illinois Administrative Code
Title 77 - PUBLIC HEALTH
Part 905 - PRIVATE SEWAGE DISPOSAL CODE
Appendix A - Illustrations and Exhibits
ILLUSTRATION I - Seepage Field Construction
Exhibit C - Gravelless System
Universal Citation: 77 IL Admin Code ยง C
Current through Register Vol. 48, No. 12, March 22, 2024
STANDARDS FOR SEEPAGE FIELD CONSTRUCTION (GRAVELLESS)
Trench Length, maximum length from point of discharge into system |
100 feet |
Trench Bottom, minimum width |
18 inches |
Trench Bottom, maximum width |
24 inches |
Trench Bottom, minimum depth |
18 inches |
Trench Bottom, maximum depth |
36 inches |
Trench Bottom, slope |
level |
Distribution Line, minimum inside diameter |
8 inches |
Distribution Line, maximum inside diameter |
10 inches |
Distribution Line, minimum earth cover |
6 inches |
Distribution Line, maximum earth cover |
24 inches |
Distribution Line, maximum slope |
level |
Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.