Line

Soil or waste pipe diam. (in.)

Fixture Units (max. number

Diameter of circuit or loop vent (in.)

11/2

2

21/2

3

4

5

Maximum Horizontal Length (ft.)

1

11/2

10

20

2

2

12

15

40

3

2

20

10

30

4

3

10

20

40

100

5

3

30

40

100

6

3

60

16

80

7

4

100

7

20

52

200

8

4

200

6

18

50

180

9

4

500

14

36

140

10

5

200

16

70

200

11

5

1,100

10

40

140

Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.