Illinois Administrative Code
Title 77 - PUBLIC HEALTH
Part 890 - ILLINOIS PLUMBING CODE
Subpart M - INSPECTIONS, TESTS, MAINTENANCE AND ADMINISTRATION
Appendix A - Plumbing Materials, Equipment, Use Restrictions and Applicable Standards
Table I - Allowed Distance from Fixture Trap to Vent
Universal Citation: 77 IL Admin Code § I
Current through Register Vol. 48, No. 52, December 27, 2024
Size of Fixture Drains (Inches) |
Maximum Allowed Distance from Trap to Vent |
11/4 |
2 ft. 6 in. |
11/2 |
3 ft. 6 in. |
2 |
4 ft. 0 in. |
3 |
5 ft. 0 in. |
4 and larger |
6 ft. 0 in. |
Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.