Maximum Number of Drainage Fixture Units (D.F.U.)

That May be Connected to:

More than 3 Stories in Height

Diameter of Pipe (inches)

Any Horizontal Fixture Branch

One Stack of 3 Stories in Height or 3 Intervals

Total for Stack

Total at One Story or Branch Interval

11/4

1

2

2

1

11/2

3

4

8

2

2

6

10

24

6

21/2

12

20

42

9

3

201

302

602

161

4

100

240

500

90

5

360

540

1,100

200

6

620

960

1,900

350

8

1,400

2,200

3,600

600

10

2,500

3,800

5,600

1,500

12

3,900

6,000

8,400

1,500

15

7,000

-

-

-

1 Not over two water closets.

2 Not over six water closets, or more than two per branch interval or per floor.

Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.