Illinois Administrative Code
Title 77 - PUBLIC HEALTH
Part 890 - ILLINOIS PLUMBING CODE
Subpart M - INSPECTIONS, TESTS, MAINTENANCE AND ADMINISTRATION
Appendix A - Plumbing Materials, Equipment, Use Restrictions and Applicable Standards
Table E - Drainage Fixture Units (D.F.U.) Per Fixture Group
Type of Fixture |
D.F.U./Fixture (Load) |
Minimum Size of Trap2 (inches) |
Bathroom groups: 1 tank water closet, 1 lavatory with 11/4 inch trap and 1 bathtub1 or shower stall |
7 |
11/4 |
1 water closet with flush valve, 1 lavatory with 11/4 inch trap and 1 bathtub or shower1 |
11 |
|
Bathtub (with or without overhead shower)1 |
2 |
11/2 |
Bathtub1 |
3 |
2 |
Bidet |
2 |
11/2 |
Clothes washer, automatic |
3 |
2 |
Dental unit or cuspidor |
1 |
11/4 |
Drinking fountain |
1/2 |
1 |
Dishwasher2, domestic |
2 |
11/2 |
Floor drains |
See Appendix A, Table F |
2 |
Lavatories: |
||
Lavatory |
1 |
11/4 |
Lavatory |
2 |
11/2 |
Lavatory, barber, beauty parlor |
2 |
11/2 |
Lavatory, dental |
1 |
11/4 |
Lavatory, surgeon's |
2 |
11/2 |
Laundry tray (1 or 2 compartments) |
2 |
11/2 |
Type of Fixture |
D.F.U./Fixture (Load) |
Minimum Size of Trap2 (inches) |
Shower stall |
3 |
2 |
Showers (group) per head2 |
3 |
2 |
Sinks: |
||
Combination sink and tray |
3 |
11/2 |
Combination sink and tray with food-disposal unit |
4 Separate Traps |
11/2 |
Flushing rim (with valve) |
8 |
3 |
Kitchen sink, domestic |
2 |
11/2 |
Kitchen sink, domestic, with food-waste grinder |
3 Separate Traps |
11/2 |
Pot, scullery, etc.2 |
4 |
11/2 |
Service (P trap) |
3 |
3 |
Service (P trap) |
2 |
2 |
Surgeon's |
3 |
11/2 |
Wash sink2 (circular or multiple), each set of faucets |
2 |
11/2 |
Urinals: |
||
Urinal, pedestal, siphon jet, blowout |
8 |
2 |
Urinal stall |
3 |
2 |
Urinal, wall integral trap |
3 |
2 |
Urinal, wall P trap, exposed |
2 |
11/2 |
Water closets: |
||
Tank operated |
4 |
3 |
Valve-operated |
8 |
3 |
1A shower head over a bathtub does not increase the fixture value.
2See Appendix A: Table F and Section 890.1330(b) for method of determining unit values of fixtures not listed in this Table or for rating of devices with intermittent flows.