Illinois Administrative Code
Title 77 - PUBLIC HEALTH
Part 890 - ILLINOIS PLUMBING CODE
Subpart M - INSPECTIONS, TESTS, MAINTENANCE AND ADMINISTRATION
Appendix A - Plumbing Materials, Equipment, Use Restrictions and Applicable Standards
Table D - Minimum Water Distribution Pipe Size

Universal Citation: 77 IL Admin Code § D
Current through Register Vol. 49, No. 13, March 28, 2025

Type of Fixture or Device (See Footnotes 1 & 2)

Pipe Size (inches)

Bathtubs

1/2

Combination sink and tray

1/2

Drinking fountain

3/8

Dishwasher (domestic)

1/2

Dishwasher (commercial)

3/4

Kitchen sink (residential)

1/2

Kitchen sink (commercial) 1 Faucet

1/2

Kitchen sink (commercial) 2 Faucets

3/4

Lavatory

3/8

Laundry tray (1, 2 or 3 compartment)

1/2

Shower (single head)

1/2

Sinks (service/slop)

1/2

Sinks (flushing rim)

3/4

Urinal (flush tank)

1/2

Urinal (direct flush valve)

3/4

Urinal (siphon jet)

1

Washing machine (automatic)

1/2

Water closet (tank type)

3/8

Water closet (flush valve type)

1

Hose bibbs

1/2

Wall hydrant

1/2

1 For fixtures not listed, the minimum supply branch shall be installed in the diameters required for similar type fixtures.

2 The fixture supply pipe shall be extended to within 12 inches of the point of connection to fixture and be within the same area and physical space as the point of connection to the fixture.

Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.