Illinois Administrative Code
Title 77 - PUBLIC HEALTH
Part 890 - ILLINOIS PLUMBING CODE
Subpart M - INSPECTIONS, TESTS, MAINTENANCE AND ADMINISTRATION
Appendix A - Plumbing Materials, Equipment, Use Restrictions and Applicable Standards
Table A - Approved Materials and Standards
All materials shall meet at least one of the approved standards listed.
Approved Building Drainage/Vent Pipe
1) |
Acrylonitrite Butadiene Styrene (ABS) Pipe |
ASTM D 2661-2011 |
|
ASTM F 628-2012 |
|||
CSA B181.1 -2011 in B1800 |
|||
Joints |
ASTM D 2235-2011 |
||
CSA B602-2010 |
|||
Solvent Cement1 |
ASTM D 2235-2011 ASTM D 3138-2011 |
||
CSA B181.1-2011 in B1800 |
|||
2) |
Brass Pipe |
ASTM B 43-2009 |
|
3) |
Cast Iron Pipe |
ASTM A 74-2009 |
|
ASTM A 888-2011 |
|||
ASTM C 564-2012 |
|||
CISPI 301-2009 |
|||
CSA B70-2012 FM 1680-1989 |
|||
4) |
Chlorinated Polyvinyl Chloride (CPVC) (Pipe and Fittings for Chemical Waste Drainage Systems) |
ASTM F2618-2009 |
|
5) |
Copper/Copper Alloy Pipe |
ASTM B 42-2010 |
|
ASTM B 302-2012 |
|||
6) |
Copper/Copper Alloy Tubing |
ASTM B 75/B75M-2011 |
|
(K-L-M or DWV)2 |
ASTM B 88-2009 |
||
ASTM B 251-2010 |
|||
ASTM B 306-2009 |
|||
7) |
Galvanized Steel Pipe2 |
ASTM A 53/A53M-2012 |
|
8) |
Glass Fiber Borosilicate Pipe3 |
ASTM C 1053-2010 |
|
9) |
High Silicon Content Cast Iron Pipe3 |
ASTM A 377-2008e1 |
|
CSA B70-2012 |
|||
10) |
Polypropylene Pipe3 |
||
CSA B137.1 -2009 in B137 |
|||
11) |
Polyvinyl Chloride (PVC) Pipe and Fittings |
ASTM D 2665-2012 |
|
ASTM D 2949-2010 |
|||
CSA B137.2 -2009 in B137 |
|||
CSA B181.2 -2011 in B1800 |
|||
12) |
Polyvinyl Chloride (PVC) Pipe with Cellular Core4 |
ASTM F891-2010 ASTM F1760-2011 |
|
Joints |
ASTM D 2855-2010 |
||
Primer |
ASTM F 656-2010 |
||
Solvent Cement1 |
ASTM D 2564-2012 ASTM D 3138-2011 |
||
13) |
Polyvinylidene Fluoride3 |
ASTM D 3222-2010 |
|
14) |
Solder |
ASTM B 32-2008 |
|
15) |
Stainless Steel - types 304 and 316L |
ASME A112.3.1-2007 (R2012) |
|
16) |
Stainless Steel Buttweld Fittings |
ASTM A 403/A 403M-2012 ASTM A 774/A 774M-2009 |
|
17) |
Stainless Steel Flanges |
ASTM A 2400/A 240M-2012a |
|
18) |
Identification of Piping Systems |
ASME A13.1 -2007 |
Agency Notes:
1 Solvent cement must be handled in accordance with ASTM F 402-1993.
2 Type M copper tubing, DWV copper tubing, and galvanized steel pipe are approved for above-ground uses only.
3 Approved for corrosive waste or corrosive soil conditions.
4 PVC pipe with cellular core is approved only for gravity drainage and venting.
5 ASME B.1.20.1-1983
Approved Materials for Building Sewer
1) |
Acrylonitrite Butadiene Styrene (ABS) Pipe |
ASTM D 2661-2011 |
|
ASTM D 2751-2005 |
|||
ASTM F 628-2012 |
|||
CSA B181.1-2011 in B1800 |
|||
Joints |
ASTM D 2235-2011 |
||
CSA B602-2010 |
|||
Solvent Cement1 |
ASTM D 2235-2011 ASTM D 3138-2011 |
||
CSA B181.1-2011 in B1800 |
|||
2) |
Asbestos Cement Pipe |
ASTM C 428/C 428M-2011e1 |
|
CSA B127.1 -1999 (R2009) |
|||
3) |
Cast Iron Soil Pipe/Fittings |
ASTM A 74-2009 |
|
CSA B70-2012 |
|||
Hubless Soil Pipe |
CISPI 301-2009 |
||
CISPI 310-2011 |
|||
CSA B70-2012 FM 1680-1989 |
|||
Rubber Gaskets |
ASTM C 564-2012 ASTM D 4161-2010 |
||
CSA B70-2012 |
|||
CSA B602-2010 |
|||
4) |
Copper/Copper Alloy Tubing |
ASTM B 88-2009 |
|
5) |
Concrete Pipe |
ASTM C 14-2011 |
|
ASTM C 76-2013 ASTM C 443-2012 |
|||
CSA B602-2010 |
|||
6) |
High-Density Polyethylene (HDPE) Pipe |
ASTM D 3350-2012 |
|
7) |
Polyvinyl Chloride (PVC) Pipe |
ASTM F 1866-2007 |
|
ASTM D 2665-2012 |
|||
ASTM D 2949-2010 |
|||
ASTM D 3034-2008 |
|||
CSA B182.1 -2011 in B1800 |
|||
CSA B182.2 -2011 in B1800 |
|||
CSA B182.4 -2011 in B1800 |
|||
CSA B181.2-2011 in B1800 |
|||
Joints |
ASTM D 2855-2010 ASTM D 3212-2013 |
||
CSA B602-2010 |
|||
Primer |
ASTM F 656-2010 |
||
Solvent Cement1 |
ASTM D 2564-2012 ASTM D 3138-2011 |
||
CSA B181.2-2011 in B1800 |
|||
8) |
Polyvinyl Chloride (PVC) Pipe with Cellular Core2 |
ASTM F 891-2010 |
|
Joints |
ASTM D 2855-2010 ASTM D 412-2006ae2 |
||
Primer |
ASTM F 656-2010 |
||
Solvent Cement1 |
ASTM D 2564-2012 ASTM D 3138-2011 |
||
9) |
Solder |
ASTM B 32-2008 |
|
10) |
Vitrified Clay Pipe2 |
ASTM C 4-2009 |
|
ASTM C 700-2013 ASTM C 425-2009 |
|||
11) |
Polypropylene Pipe2 |
ASTM F 2389-2010 AWWA C901-2008 AWWA C906-2012 (Material Code PE3408)3 (Material Codes PE2406 and PE3406)4 |
|
12) |
Identification of Piping Systems |
ASME A13.1-2007 |
Agency Notes:
1 Solvent cement must be handled in accordance with ASTM F 402-1988.
2 PVC pipe with cellular core and vitrified clay pipe are approved only for gravity drainage.
3 Dimension Ratio (DR) 17 or less.
4 Dimension Ratio (DR) 13.5 or less.
Approved Materials for Water Service Pipe
1) |
Acrylonitrite Butadiene Styrene (ABS) Pipe2 |
ASTM D 1527-2005 |
||
Joints |
ASTM D 2235-2011 |
|||
Solvent Cement1 |
ASTM D 2235-2011 |
|||
2) |
Brass Pipe2 |
ASTM B 43-2009 |
||
3) |
Cast Iron (ductile iron)2 |
ASTM A 377-2008e1 |
||
Water Pipe |
CSA B70-2012 AWWA C151-2009 |
|||
4) |
Chlorinated Polyvinyl Chloride (CPVC) Pipe2 |
ASTM D 2846/D 2846M-2009be1 |
||
ASTM F 441/F 441M-2012 |
||||
ASTM F 442/F 442M-2012 |
||||
CSA B137.6 -2009 in B137 |
||||
Joints |
ASTM D 2846/D 2846M-2009be1 |
|||
CSA B137.6-2009 in B137 |
||||
Solvent Cement1 |
ASTM F 493-2010 |
|||
CSA B137.6-2009 in B137 |
||||
5) |
Copper/Copper Alloy Pipe2, 3 |
ASTM B 42-2010 |
||
ASTM B 302-2012 |
||||
6) |
Copper/Copper Alloy Tubing2,3 |
ASTM B 88-2009 |
||
7) |
Galvanized Steel Pipe2 |
ASTM A 53/A 53M-2012 |
||
8) |
Poly Butylene (PB) Pipe/Tubing2 |
CSA B137.8 -2009 in B137 |
||
9) |
Polyethylene (PE) Pipe2 |
ASTM D 2239-2012a AWWA C901-2008 AWWA C906-2012 (Material Code PE3408)4 (Material Codes PE2406 and PE3406)5 |
||
10) |
Polyethylene (PE) Tubing2 |
ASTM D 2737-2012a |
||
CSA B137.1-2009 in B137 |
||||
11) |
Polypropylene Pipe2 |
ASTM F 2389-2010 |
||
12) |
Polyvinyl Chloride (PVC) Pipe2 |
ASTM D 1785-2012 |
||
ASTM D 2241-2009 |
||||
ASTM D 2672-2009 ASTM F 477-2010 AWWA C900-2007 |
||||
CSA B137.3 -2009 in B137 |
||||
Joints |
ASTM D 2855-2010 ASTM D 3139-2011 |
|||
CSA B137.2-2009 in B137 |
||||
CSA B137.3-2009 in B137 |
||||
Primer |
ASTM F 656-2010 |
|||
Solvent Cement1 |
ASTM D 2564-2012 |
|||
CSA B137.3-2009 in B137 |
||||
13) |
Stainless Steel Pipe2 |
ASTM A 312/A 312M-2012a ASTM A 403/A 403M-2012 ASTM A 511/A 511M-2012 |
||
14) |
Welded Copper Water Tube2 |
ASME B31.1 -2012 ASTM B 447-2012a WK and WL |
||
15) |
Solder |
ASTM B 32-2008 |
Agency Notes:
1 Solvent cement must be handled in accordance with ASTM F 402-1988.
2 Water service pipe must meet the appropriate NSF standard for potable water.
3 Type K or L copper may be installed underground.
4 Dimension Ratio (DR) 17 or less.
5 Dimension Ratio (DR) 13.5 or less.
6 ASME B.1.20.1-1983.
Approved Materials for Water Distribution Pipe
1) |
Brass Pipe2 |
ASTM B 43-2009 |
|||
2) |
Chlorinated Polyvinyl Chloride2 (CPVC) Pipe/Tubing |
ASTM D 2846/D 2846M-2009be1 |
|||
ASTM F 441/F 441M-2012 |
|||||
ASTM F 442/F 442M-2012 |
|||||
CSA B137.6-2009 in B137 |
|||||
Joints |
ASTM D 2846/D 2846M-2009be1 |
||||
CSA B137.6-2009 in B137 |
|||||
Solvent Cement1 |
ASTM F 493-2010 |
||||
CSA B137.6-2009 in B137 |
|||||
3) |
Copper/Copper Alloy Pipe2 |
ASTM B 42-2010 |
|||
ASTM B 302-2012 AWWA C606-2011 |
|||||
4) |
Copper/Copper Alloy Tubing2 |
ASTM B 88-2009 |
|||
5) |
Cross Linked Polyethylene2 |
ASTM F 876-2013a |
|||
5) |
Distribution Systems |
ASTM F 877-2011a |
|||
Joints |
ASTM F 1807-2012 ASTM F 1960-2012 ASTM F 2080-2012 ASTM F 2098-2008 ASTM F 2159-2011 ASSE 1061-2011 |
||||
CSA B137.5 -2009 in B137 |
|||||
6) |
Galvanized Steel Pipe2 |
ASTM A 53-2012 AWWA C606-2011 |
|||
7) |
Poly Butylene (PB) Pipe/Tubing2 |
||||
CSA B137.8-2009 in B137 |
|||||
8) |
Polypropylene Pipe2 |
ASTM F 2389-2010 |
|||
9) |
Polyvinyl Chloride (PVC) Pipe2, 3 |
ANSI/NEMA Z535.1 -2006 (R2011) ASTM D 1785-2012 |
|||
ASTM D 2241-2009 |
|||||
ASTM D 2672-2009 |
|||||
CSA B137.3-2009 in B137 |
|||||
Joints |
ASTM D 2855-2010 ASTM F 441/F 441M-2012 |
||||
CSA B137.2-2009 in B137 |
|||||
CSA B137.3-2009 in B137 |
|||||
Primer |
ASTM F 656-2010 |
||||
Solvent Cement1 |
ASTM D 2564-2012 |
||||
CSA B137.3-2009 in B137 |
|||||
10) |
Stainless Steel Pipe2 |
ASTM A 312/A 312M-2012 ASTM A 403/A 403M-2012 ASTM A 511/A 511M-2012 |
|||
11) |
Welded Copper Water Tube2 |
ASTM B 447-2012a WK, WL and WM |
|||
12) |
Solder |
ASTM B 32-2008 |
Agency Notes:
1 Solvent cement must be handled in accordance with ASTM F 402-1988.
2 Water distribution pipe must meet the appropriate NSF standard for potable water. Plastic shall be rated at 160 psi at 73.4 degrees Fahrenheit.
3 Use for cold or tempered water only.
4 ASME B.1.20.1-1983.
5 Safety Color.
Approved Materials and Standards for
Plumbing Fixtures and Fixture Fittings
1) |
Bathtub Liners (plexiglass/ABS or acrylic/plastic) |
IAPMO/ANSI Z124.8 -2013 |
2) |
Bathtubs, Plastic |
|
CSA B45.5 -2011/IAPMO Z124-2011 |
||
3) |
Bidets |
ASME A112.19.2-2013/CSA B45.1 -2013 |
4) |
Enameled Cast Iron and Enameled Steel Plumbing Fixtures |
ASME A112.19.1-2008/CSA B45.2 -2008 |
5) |
Fittings: |
|
Plumbing Fixture Fittings (metering valves, faucets, etc.) |
ASME A112.18.1-2012/CSA B125.1 -2012 |
|
Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, Hot Tubs and Whirlpool Bathtub Appliances |
ANSI/APSP 16-2011 CSA C22.2 No. 218.1 -M1989 (R2011) CSA C22.2 No. 218.2 -1993 (R2008) |
|
6) |
Floor Drains and Trench Drains |
ASME A112.6.3-2001 (R2007) |
CSA B79-2008 |
||
7) |
Flushometer Bowls |
ASME A112.19.2-2013/CSA B45.1-2013 |
CSA B125.3 -2011 |
||
Flushometers |
ASSE 1037-1990 |
|
CSA B125.3-2011 |
||
8) |
Grease Interceptors |
ASME A112.14.3-2000 (R2004) |
9) |
Low Consumption (1.6 gpf) Water Closets1 |
ASME A112.19.2-2013/CSA B45.1-2013 ASME A112.19.14-2006 (R2-11) |
10) |
Plastic Lavatory |
|
CSA B45.5-2011/IAPMO Z124-2011 |
||
11) |
Plastic Shower Receptors/Shower Stalls |
|
CSA B45.5-2011/IAPMO Z124-2011 |
||
12) |
Plastic Water Closets Bowls/Tanks |
|
CSA B45.5-2011/IAPMO Z124-2011 |
||
13) |
Plastic Urinals Fixtures |
CSA B45.5-2011/IAPMO Z124-2011 |
14) |
Porcelain Enameled Formed Steel Plumbing Fixtures, including Bathtub Liners |
ASME A112.19.1-2008/CSA 45.2-2008 |
15) |
Stainless Steel Plumbing Fixtures (Residential) |
ASME A112.19.3-2008/CSA B45.4 -2008 |
16) |
Vitreous China Plumbing Fixtures |
ASME A112.19.2-2013/CSA B45.1-2013 |
17) |
Vitreous China Nonwater Urinals |
ASME A112.19.19-2006 (R2011) |
18) |
Whirlpool Bathtub Appliances |
ASME A112.19.7-2012/CSA B45.10 -2012 |
CSA C22.2 No. 218.2-1993 (R2008) |
Agency Note:
The water pressure at each fixture installation shall meet the manufacturer's minimum recommended level for the fixture.
Approved Standards for Plumbing
Appliances/Appurtenances/Devices
1) |
Anti-Backflow Freezeless Wall Hydrants |
ASSE 1019-2011 |
ASME A112.18.1-2012/CSA B125.1-2012 |
||
2) |
Anti-Scald Control Valve |
ASSE 1016-2011/ASME A112.1016 -2011/CSA B125.16 -2011 |
3) |
Anti-siphon Self-Drain Frost Proof Sillcock |
ASSE 1019-2011 CSA B125.3-2012 |
4) |
Automatic Ice Making Equipment |
NSF/ANSI 12-2009 |
CSA C22.2 No. 120-M1991 (R2008) |
||
5) |
Automatic Storage Type Water Heater Less Than 75,000 BTU/HR |
ANSI Z21.10.1-2009/CSA 4.1 -2009 |
ASHRAE 90.1 2010 ASHRAE 90.2 -2007 ANSI Z21.10.1a-2009/CSA 4.1a-2009 ANSI Z21.10.1b-2011/CSA 4.1b-2011 |
||
6) |
Back Water Valves |
ASME A112.14.1-2003 (R2012) |
CSA B181.1-2011 in B1800 |
||
CSA B181.2-2011 in B1800 |
||
CSA B182.1-2011 in B1800 |
||
CSA B70-2012 |
||
7) |
Circulating Tank, Instantaneous |
ANSI Z21.10.1-2009/CSA 4.1-2009 ANSI Z21.10.1a-2009/CSA 4.1a-2009 ANSI Z21.10.1b-2011/CSA 4.1b-2011 |
ANSI Z21.10.3-2011/CSA 4.3 -2011 |
||
ANSI Z21.13 -2010/CSA 4.9 -2010 ANSI Z21.13a-2010/CSA 4.9a-2010 ANSI Z21.13b-2012/CSA 4.9b-2012 |
||
CSA B140.12 -2003 (R2008) |
||
CSA C22.2 No. 110-1994 (R2009) UL 499-2005 |
||
8) |
Circulating Tank, Instantaneous, Automatic |
ANSI Z21.10.3-2011/CSA 4.3-2011 ANSI Z21.13-2010/CSA 4.9-2010 ANSI Z21.13a-2010/CSA 4.9a-2010 ANSI Z21.13b-2012/CSA 4.9b-2012 UL 174-2004 |
CSA 4.1-2011 |
||
CSA B140.12-2003 (R2008) |
||
CSA C22.2 No. 110-1994 (R2009) |
||
9) |
Detergent/Chemical Feeders for Commercial Use |
ASSE 1055-2009 |
CSA C22.2 No. 0-2010 |
||
CSA C22.2 No. 0.4 -2004 (R2009) |
||
CSA C22.2 No. 68-1992 (R2008) |
||
CSA C22.2 No. 142-M1987 (R2009) |
||
10) |
Dishwashing Machine (Commercial) |
ASSE 1004-2008 ANSI Z83.21 -2005/CSA C22.2 No. 168-2005 ANSI Z83.21a-2012/CSA C22.2 No. 168a-2012 |
CSA C22.2 No. 0-2010 |
||
CSA C22.2 No. 0.4-2004 (R2009) |
||
11) |
Dishwashing Machine (Residential) |
ASSE 1006-1986 (R1989) |
CSA C22.2 No. 167-2008 |
||
12) |
Diverters for Residential - Anti-Siphon |
|
ASME 1112.18.1-2012/CSA B125.1-2012 |
||
13) |
Double Check Detector Assembly |
ASSE 1048-2011 |
CSA B64-2011 |
||
14) |
Double Check With Atmospheric Vent |
ASSE 1012-2009 |
CSA B64-2011 |
||
15) |
Double Check Valve Assembly |
ASSE 1015-2011 |
CSA B64-2011 |
||
16) |
Drinking Fountains |
ASHRAE 18-2008 (R2013) UL 399-2008 ASME A112.19.2-2013/CSA 45.1-13 |
17) |
Drinking Water Treatment Units - Health Effects |
NSF/ANSI 53-2011a |
18) |
Drinking Water Treatment Units - Aesthetic Effects |
NSF/ANSI 42-2011 |
19) |
Drinking Water Treatment Chemicals |
NSF/ANSI 60-2012 |
20) |
Dual Check Valve |
ASSE 1024-2004 |
CSA B64-2011 |
||
21) |
Duel Check Valve (Carbonated Beverage) (Relief Port Required) |
ASSE 1022-2003 CSA B64-2011 |
22) |
Food Waste Disposal (Commercial) |
ASSE 1009-1990 |
CSA C22.2 No. 1-2010 |
||
CSA C22.2 No. 68-1992 |
||
23) |
Food Waste Disposal (Residential) |
ASSE 1008-2006 |
CSA C22.2 No. 0-2010 |
||
CSA C22.2 No. 68-2008 |
||
24) |
Gas Water Heater Above 75,000 BTU |
ANSI Z21.10.3-2011/CSA 4.3-2011 |
25) |
Gas Water Heater 75,000 BTU or Less |
ANSI Z21.10.1-2009/CSA 4.1-2009 ANSI Z21.10.1a-2009/CSA 4.1a-2009 |
ANSI Z21.10.1b-2011/CSA 4.1b-2011 |
||
26) |
Gas Water Heater (Continuous Use) |
ANSI Z21.10.1-2009/CSA 4.1-2009 ANSI Z21.10.1a-2009/CSA 4.1a-2009 |
ANSI Z21.10.1b-2011/CSA 4.1b-2011 |
||
27) |
Gas Water Heater - Space Heating |
ANSI Z21.10.1-2009/CSA 4.1-2009 ANSI Z21.10.1a-2009/CSA 4.1a-2009 |
ANSI Z21.10.1b-2011/CSA 4.1b-2011 |
||
28) |
Grease Interceptors |
PDI-G 101-2010 ASME A112.14.3-2000 (R2004) |
29) |
Handheld Showers |
ASSE 1014-2005 ASSE 1016-2011/ASME A112.1016-2011/CSA B125.16-2011 |
30) |
Home Laundry Equipment |
ASSE 1007-1986 (R1992) |
CSA C22.2 No. 0-2010 |
||
CSA C22.2 No. 0.4-2004 (R2009) |
||
CSA C22.2 No. 169-1997 (R2012) |
||
31) |
Hot Water Dispensers-Electrical |
ASSE 1023-1979 |
CSA C22.2 No. 64-2010 |
||
32) |
Hot Water Generating/Heat Recovery Equipment |
NSF/ANSI 5-2012 |
33) |
Ice Makers |
UL 563-2009 |
CSA B45-2008 |
||
CSA C22.2 No. 0-2010 |
||
CSA C22.2 No. 0.4-2004 (R2009) |
||
CSA C22.2 No. 63-1993 (R2008) |
||
CSA C22.2 No. 120-M1991 (R2008) |
||
34) |
Individual Pressure Balancing In-line valves for individuals fixture fittings |
ASSE 1066-1997 |
35) |
Mixing Valves Automatic Compensating Valves for Individual Shower and Tub/Shower Combinations |
ASSE 1016-2011/ASME A112.1016-2011/CSA B125.16-2011 |
Temperature Actuated Mixing Valves for Hot Water Distribution |
ASSE 1017-2009 |
|
Automatic Temperature Control Mixing Valves |
ASSE 1069-2005 |
|
Water Temperature Limiting Devices |
ASSE 1070-2004 |
|
Mixing Valves for Plumbed Emergency Equipment |
ASSE 1071-2012 |
|
36) |
Oil Fired Water Heaters |
UL 732-2010 |
CSA B140.0 -2003 (R2008) |
||
CSA B140.12-2003 (R2008) |
||
CSA C22.2 No. 0-2010 |
||
CSA C22.2 No. 3-M1988 (R2009) |
||
37) |
Pressure Relief Valve |
ANSI Z21.22 -1999 (R2008)/CSA 4.4 -M1999 (R2008) |
ANSI Z21.22a-2000 (R2008)/CSA 4.4a-2000 (R2008) |
||
ANSI Z21.22b-2001 (R2008)/CSA 4.4b-2001 (R2008) |
||
38) |
Pressurized Flushing Device |
ASSE 1037-1990 |
39) |
Reduced Pressure Detector Assembly |
ASSE 1047-2011 |
CSA B64-2011 |
||
40) |
Reduced Pressure Principle Backflow Preventer |
ASSE 1013-2011 |
CSA B64-2011 |
||
41) |
Refuse Compactors/Compactor System |
NSF/ANSI 13-2012 |
CSA C22.2 No. 0-2010 |
||
CSA C22.2 No. 68-2008 |
||
42) |
Relief Valves For Hot Water System |
ANSI Z21.22-1999 (R2008)/CSA 4.1-M1999 (R2008) |
ANSI Z21.22a-2000 (R2008)/CSA 4.4a-2000 (R2008) |
||
ANSI Z21.22b-2001 (R2008)/CSA 4.4b-2001 (R2008) |
||
43) |
Reverse Osmosis Drinking Water Treatment System |
NSF/ANSI 58-2012 |
44) |
Spray Type Dishwashing Machine for Commercial Use |
NSF/ANSI 3-2012 CSA C22.2 No. 0-2010 |
CSA C22.2 No. 0.4-2004 (R2009) |
||
ANSI Z83.21-2005/CSA C22.2 No. 168-2005 ANSI Z83.21a-2012/CSA C22.2 No. 168a-2012 |
||
45) |
Trap Seal Primer Valve |
ASSE 1018-2001 |
CSA B125.3-2012 |
||
46) |
Vacuum Breakers, Anti-siphon |
ASSE 1001-2008 |
CSA B64-2011 |
||
47) |
Vacuum Breakers Hose Connection |
ASSE 1011-2004 |
CSA B64-2011 |
||
48) |
Vacuum Breaker (Laboratory Faucet) |
ASSE 1035-2008 |
CSA B64-2011 |
||
49) |
Vacuum Breakers Pressure Type |
ASSE 1020-2004 |
CSA B64-2011 |
||
50) |
Vacuum Relief Valve |
ANSI Z21.22b-2001 (R2008) |
CSA B64-2011 |
||
51) |
Vending Machine for Food/Beverage |
NSF/ANSI 25-2012 |
CSA C22.2 No. 0-2010 |
||
CSA C22.2 No. 120-M1991 (R2008) |
||
CSA C22.2 No. 128-1995 (R2009) ASSE 1002-2008 |
||
52) |
Water Closet Personal Hygiene Devices |
ASME A112.4.2-2009 |
53) |
Water Closet Tank Ballcock |
ASSE 1002-2008 CSA B64-2011 |
CSA B125.3-2012 |
||
54) |
Water Hammer Arresters |
ASSE 1010-2004 |
55) |
Water Heater Drain Valve |
ASME A121.18.1-2011/CSA B125.1-2011 |
56) |
Water Pressure Reducing Valves (Domestic) |
ASSE 1003-2009 |
CSA B356-2010 |
||
57) |
Water Softener and Treatment Devices |
NSF/ANSI 44-2012 |
Approved Standards for Fittings
1) |
Cast Iron Threaded Drainage Fittings |
ASME B16.12 -2009 |
2) |
Cast Copper Alloy Solder Pressure Fittings |
ASME B16.18 -2012 |
3) |
Cast Copper Alloy Solder Drainage Fitting (DWV) |
ASME B16.23 -2011 |
4) |
Copper Fittings |
ASME B16.15 -2011 |
ASME B16.51 -2011 |
||
ASME B16.18-2012 |
||
ASME B16.22 -2012 |
||
ASME B16.23-2011 |
||
ASME B16.26 -2011 |
||
ASME B16.29 -2012 |
||
NSF/ANSI 61-2012 |
||
5) |
Forged Steel Fittings, Socket, Welded, Threaded |
ASME B16.11 -2011 |
6) |
Gray Iron/Ductile Iron |
AWWA C 110-2009 |
AWWA C 151-2009 |
||
7) |
Malleable Iron |
ASME B 16.3 -2011 |
8) |
Plastic |
ASTM D 2466-2006 |
ASTM D 2467-2006 |
||
ASTM D 2564-2012 |
||
ASTM F409-2012 |
||
ASTM F438-2009 |
||
ASTM F439-2012 |
||
CSA B137.3-2009 in B137 |
||
CSA B181.2-2011 in B1800 |
||
CSA B182.1-2011 in B1800 |
||
CSA B137.6-2009 in B137 |
||
CSA B137.6-1999 in B137 |
||
9) |
Plumbing Fixture Fittings (Metering valves, faucets, etc.) |
ASME A112.18.1-2012/CSA B125.1-2012 |
10) |
Steel |
ASME B 16.9 -2012 |
ASME B 16.11-2011 |
||
11) |
Wrought Copper/Bronze Solder Pressure Fitting |
ASME B 16.22-2012 |
12) |
Wrought Copper and Wrought Copper Alloy Solder (Drainage Fittings) |
ASME B16.29-2012 |
ASME B16.22-2012 |
||
13) |
Wrought Steel Buttwelding Fittings |
ASME B16.9-2012 |
14) |
Wrought Steel Buttwelding Short Radius Ells |
ASME B16.9-2012 |