Illinois Administrative Code
Title 77 - PUBLIC HEALTH
Part 870 - MANUFACTURED HOME INSTALLATION CODE
Table H - Multi-Section Fastening Schedule
Universal Citation: 77 IL Admin Code ยง H
Current through Register Vol. 48, No. 12, March 22, 2024
CONNECTOR LOCATION |
FASTENER SIZE |
FASTENER ANGLE |
FASTENER SPACING |
Roof ridge beam connection |
1/2 inch carriage bolts |
90 degrees |
48 inches on center |
Roof ridge beam connection |
3/8 inch lag screws with washers |
45 degrees or less |
24 inches on center |
Roof rafter connection |
4 inch by 10 inch 18 gauge straps with 10-10d nails |
90 degrees |
48 inches on center |
Floor rim joist connection |
3/8 inch lag screws with washers |
45 degrees or less |
32 inches on center |
Floor connection |
Marriage clips |
90 degrees |
Where installed |
Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.