a) No part of a unit shall be located within a setback zone established pursuant to Section 14.2 or 14.3 of the Act.
b) No part of a unit shall be located within the recharge zone or within 366 meters (1200 feet), vertically or horizontally, of that portion of a stratigraphic unit containing Class I or Class III groundwater as defined at 35 Ill. Adm. Code 620, unless:
c) Subsection (b) shall not apply to units that accept only beneficially useable waste.
d) A facility located within 152 meters (500 feet) of the right of way of a township or county road or State or interstate highway shall have its operations screened from view by a barrier of natural objects, fences, barricades or plants no less than 2.44 meters (8 feet) in height.
e) No part of a unit shall be located closer than 152 meters (500 feet) from an occupied dwelling, school or hospital that was occupied on the date when the operator first applied for a permit to develop the unit or the facility containing the unit, unless the owner of such dwelling, school or hospital provides permission to the operator, in writing, for a closer distance.