Illinois Administrative Code
Title 35 - ENVIRONMENTAL PROTECTION
Part 611 - PRIMARY DRINKING WATER STANDARDS
Subpart B - FILTRATION AND DISINFECTION
Section 611.242 - Filtered PWSs
Current through Register Vol. 48, No. 38, September 20, 2024
Each supplier providing filtration treatment must provide disinfection treatment:
a) The disinfection treatment must sufficiently ensure that the system's total treatment processes achieve at least 99.9 percent (3-log) inactivation or removal of Giardia lamblia cysts and at least 99.99 percent (4-log) inactivation or removal of viruses.
b) The RDC in the water entering the distribution system, measured as Sections 611.531(b) and 611.533(b) specify, cannot be less than 0.2 mg/L for more than four hours.
c) RDC in the Distribution System
where: a |
= |
The number of times when the supplier measured the RDC; |
b |
= |
The number of times when the supplier did not measure the RDC but did measure HPC; |
c |
= |
The number of times when the supplier measured but did not detect RDC but did not measure HPC; |
d |
= |
The number of times when the supplier measured but did not detect the RDC, and HPC is greater than 500/ml; and |
e |
= |
The number of times when the supplier did not measure the RDC, and HPC is greater than 500/ml. |
BOARD NOTE: This Section derives from 40 CFR 141.72(b).