Illinois Administrative Code
Title 35 - ENVIRONMENTAL PROTECTION
Part 570 - DESIGN AND MAINTENANCE CRITERIA REGARDING RUNOFF FIELD APPLICATION SYSTEMS
Subpart B - DESIGN CRITERIA
Appendix A - Design Procedure Outlined

Universal Citation: 35 IL Admin Code ยง A
Current through Register Vol. 48, No. 38, September 20, 2024

DESIGN PROCEDURE OUTLINED

1. Collect Site Specific Data

a. Types and Areas (sft) contributing drainage

b. Slope of Field Application Area (FAA) - Appendix D

c. Soil Infiltration Rate (SI) of FAA - Appendix C

2. Calculate Runoff Volume and Total Drainage Area

Working Table in Appendix B

3. Settling Basin Design

4.5 cft/100 sft of drainage area + 10% extra volume

Dimensions from Appendix I

4. Field Application Area Design

FAA = (VR x 12)/((2 x SI) - 1.69) (square feet)

Dimensions from Appendix E

5. Calculate Flow onto Field Application Area

Flows from Appendix G

or

Qf = (.0026) (FAA) (gpm)

6. Effluent Transport System Design

Recommended Designs from Appendix F

7. Junction Box Design

Recommended Design from Appendix H

8. Distribution Manifold Design

Recommended Designs from Appendix H

Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.