a) Groundwater samples shall be collected by one of the following methods:
1) Peristaltic
pumps;
2) Submersible diaphragm
pumps;
3) Bailing method using
stainless steel or PVC materials;
b) Air lift or nitrogen lift pumping equipment shall not be used.
c) Groundwater samples shall be filtered at the time of collection using a 0.45 micron filter or equivalent, however laboratory filtration is acceptable provided it is performed within 15 minutes from the time of collection. Groundwater samples shall be preserved and analyzed in accordance with Standard Methods for the Examination of Water and Wastewater (14th edition).
Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.