Illinois Administrative Code
Title 35 - ENVIRONMENTAL PROTECTION
Part 375 - COMBINED SEWER OVERFLOW EXCEPTION CRITERIA AND FIRST FLUSH DETERMINATION
Subpart B - WATER QUALITY INVESTIGATION
Section 375.204 - Phase III - Detailed Water Quality Evaluation
Universal Citation: 35 IL Admin Code ยง 375.204
Current through Register Vol. 48, No. 38, September 20, 2024
Areas to be addressed in a detailed water quality survey shall include, consistent with 35 Ill. Adm. Code 306.361(d):
a) water column chemistry -
1) upstream/downstream and overflow
sampling;
2) wet weather/dry
weather sampling;
3) diurnal
sampling for dissolved oxygen (D.O.);
4) parameters generally will include
BOD5, suspended solids, volatile suspended solids,
ammonia. Other parameters may become important depending on the nature of the
overflow; and
5) other parameters
as deemed appropriate relative to 35 Ill. Adm. Code
375.302(a)(8).
b) sediment analysis -
1) sediment oxygen demand;
2) percent volatile matter;
3) particle size distribution; and
4) other parameters as deemed appropriate
relative to 35 Ill. Adm. Code
375.302(a)(8).
c) biological survey -
1) benthic macroinvertebrates;
2) fishes; and
3) plant productivity assessment (algal
blooms).
d) hydraulic and hydrologic factors including storm hydrographs for receiving stream and overflow.
Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.