A single topographic map of the proposed project and the area within 2,500 ft. of the project shall be submitted as a part of the engineering design. Segmented maps may be provided for large projects. The topographic map shall show the following information:

a) Application area boundaries including buffer zones;

b) Treatment and storage facilities;

c) Piping and layout of the irrigation system;

d) Present and proposed land use regarding residences, buildings, developments, public access areas, etc;

e) Present and proposed water supply wells and abandoned wells and shafts;

f) Direction of groundwater movement and any points of groundwater resurfacing;

g) Surface waters and waterways, wetlands and 10-year floodplains;

h) Subsurface drainage tiles and storm sewers; and

i) Slopes of the application areas.

Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.