Illinois Administrative Code
Title 35 - ENVIRONMENTAL PROTECTION
Part 370 - ILLINOIS RECOMMENDED STANDARDS FOR SEWAGE WORKS
Subpart G - SETTLING
Section 370.730 - Protection and Service Facilities

Current through Register Vol. 48, No. 38, September 20, 2024

a) Operator Protection

All settling tanks shall be equipped to enhance safety for operators. Such features shall appropriately include machinery covers, life lines, stairways, walkways, handrails and slip-resistant surfaces. If sidewalls are extended more than three feet above the liquid level or four feet above ground level, convenient walkways must be provided to facilitate housekeeping and maintenance.

b) Mechanical Maintenance Access

The design shall provide for convenient and safe access to routine maintenance items such as gear boxes, scum removal mechanisms, baffles, weirs, inlet stilling baffle area, and effluent channels.

c) Electrical Fixtures and Controls

Electrical fixtures and controls in enclosed settling basins shall meet the requirements of the National Electric Code for Class I, Group D, Division 1 locations. The fixtures and controls shall be located so as to provide convenient and safe access for operation and maintenance. Adequate area lighting shall be provided.

Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.