a) The on-road remote sensing test equipment shall consist of the following:

1) An infrared SDM capable of measuring the concentration of HC, CO, and CO2 present in an in-use vehicle;

2) A camera system that automatically photographs vehicle license plates;

3) A system that links each emission record to the correct vehicle license plate photograph; and

4) A laser based speed and acceleration measurement system.

b) The Infrared SDM shall be of a design certified to meet the following accuracy requirements:

Pollutant

Range

Accuracy

HC

ALL

±150 ppm or ±15 percent of expected HC Concentration

CO

[LESS THAN OR EQUAL TO] 3.0 percent

±10 percent or 0.25 percent (Whichever is greater)

> 3.0 percent

±15 percent

c) The speed and acceleration measurement system shall be of a design certified to measure vehicle speed to within ±0.5 miles per hour and vehicle acceleration to within ±0.3 miles per hour per second at the moment exhaust is measured.

Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.