Illinois Administrative Code
Title 35 - ENVIRONMENTAL PROTECTION
Part 219 - ORGANIC MATERIAL EMISSION STANDARDS AND LIMITATIONS FOR THE METRO EAST AREA
Subpart Q - LEAKS FROM SYNTHETIC ORGANIC CHEMICAL AND POLYMER MANUFACTURING PLANT
Section 219.433 - Performance and Testing Requirements
Current through Register Vol. 48, No. 38, September 20, 2024
a) For the purpose of demonstrating compliance with the TRE index value in Section 219.432(c) of this Subpart, an engineering assessment shall be made to determine process vent stream flow rate, net heating value, and VOM emission rate for the representative operating conditions expected to yield the lowest TRE index value. The source shall also calculate the TRE index values pursuant to the equations contained within Appendix G (b)(1) of this Part.
b) For the purpose of demonstrating compliance with the control requirements in Section 219.432 of this Subpart, the chemical manufacturing process unit shall be run at representative operating conditions and flow rates during any performance test.
c) The following methods in 40 CFR 60, incorporated by reference at Section 219.112 of this Part, shall be used to demonstrate compliance with the reduction efficiency requirement listed in Section 219.432(a)(1) of this Subpart.
where:
Cc |
= |
Concentration of VOM (minus methane and ethane) corrected to 3 percent O2 dry basis, ppmv. |
CVOM |
= |
Concentration of VOM (minus methane and ethane), dry basis, ppmv |
%O2d |
= |
Concentration of oxygen, dry basis, percent by volume. |
where:
R |
= |
Emission reduction, percent by weight. |
Ei |
= |
Mass rate of VOM (minus methane and ethane) entering the control device, kg VOM/hr. |
Eo |
= |
Mass rate of VOM, less methane and ethane discharged to the atmosphere, kg VOM/hr. |
where:
Cij, Coj |
= |
Concentration of sample component "j" of the gas stream at the inlet and outlet of the control device, respectively, dry basis, ppmv. |
Mij, Moj |
= |
Molecular weight of sample component "j" of the gas stream at the inlet and outlet of the control device, respectively, grams per gram-mole. |
Qi, Qo |
= |
Flow rate of gas stream at the inlet and outlet of the control device, respectively, dry scm/min. |
K2 |
= |
2.494 x 10-6 (liters per minute) (gram-mole per scm) (kg/g)(min/hr), where standard temperature for (gram-mole per scm) is 20° C. |
where:
CVOM |
= |
Concentration of VOM (minus methane and ethane), dry basis, ppmv. |
Cj |
= |
Concentration of sample component "j", dry basis, ppmv. |
n |
= |
Number of components in the sample. |
d) When a flare is used to comply with the control requirements of this rule, the flare shall comply with the requirements of 40 CFR 60.18, incorporated by reference at Section 219.112 of this Part.