Illinois Administrative Code
Title 35 - ENVIRONMENTAL PROTECTION
Part 219 - ORGANIC MATERIAL EMISSION STANDARDS AND LIMITATIONS FOR THE METRO EAST AREA
Subpart H - PRINTING AND PUBLISHING
Section 219.416 - Monitoring Requirements for Letterpress Printing Lines

Current through Register Vol. 48, No. 38, September 20, 2024

a) Afterburners for Heatset Web Letterpress Printing Lines. If an afterburner is used to demonstrate compliance, the owner or operator of a heatset web letterpress printing line subject to Section 219.413(a)(1)(B) of this Subpart shall:

1) Install, calibrate, maintain, and operate temperature monitoring devices with an accuracy of 3oC or 5oF on the afterburner in accordance with Section 219.105(d)(2) of this Part and in accordance with the manufacturer's specifications. Monitoring shall be performed at all times when the afterburner is operating; and

2) Install, calibrate, operate, and maintain, in accordance with manufacturer's specifications, a continuous recorder on the temperature monitoring devices, such as a strip chart, recorder or computer, with at least the same accuracy as the temperature monitor.

b) Other Control Devices for Heatset Web Letterpress Printing Lines. If a control device other than an afterburner is used to demonstrate compliance, the owner or operator of a heatset web letterpress printing line subject to this Subpart shall install, maintain, calibrate, and operate such monitoring equipment as set forth in the owner or operator's plan approved by the Agency and USEPA pursuant to Section 219.413(b) of this Subpart.

c) Cleaning Solution

1) The owner or operator of any letterpress printing line relying on the VOM content of the cleaning solution to comply with Section 219.413(a)(2)(A) of this Subpart must:
A) For cleaning solutions that are prepared at the source with equipment that automatically mixes cleaning solvent and water (or other non-VOM):
i) Install, operate, maintain, and calibrate the automatic feed equipment in accordance with manufacturer's specifications to regulate the volume of each of the cleaning solvent and water (or other non-VOM), as mixed; and

ii) Pre-set the automatic feed equipment so that the consumption rates of the cleaning solvent and water (or other non-VOM), as applied, comply with Section 219.413(a)(2)(A) of this Subpart;

B) For cleaning solutions that are not prepared at the source with automatic feed equipment, keep records of the usage of cleaning solvent and water (or other non-VOM) as set forth in Section 219.417(c)(2) of this Subpart.

2) The owner or operator of any letterpress printing line relying on the vapor pressure of the cleaning solution to comply with Section 219.413(a)(2)(B) of this Subpart must keep records for such cleaning solutions used on any such lines as set forth in Section 219.417(e)(2)(C) of this Subpart.

Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.