Illinois Administrative Code
Title 35 - ENVIRONMENTAL PROTECTION
Part 218 - ORGANIC MATERIAL EMISSION STANDARDS AND LIMITATIONS FOR THE CHICAGO AREA
Subpart F - COATING OPERATIONS
Section 218.217 - Wood Furniture Coating and Flat Wood Paneling Coating Work Practice Standards
Current through Register Vol. 48, No. 38, September 20, 2024
a) Spray booth cleaning. Each owner or operator of a source subject to the limitations of Section 218.204(l) of this Subpart shall not use compounds containing more than 8.0 percent, by weight, of VOM for cleaning spray booth components other than conveyors, continuous coaters and their enclosures, and metal filters, unless the spray booth is being refurbished. If the spray booth is being refurbished, that is, the spray booth coating or other material used to cover the booth is being replaced, the affected source shall use no more than 1.0 gallon of organic solvent to prepare the booth prior to applying the booth coating.
b) Application equipment requirements. No owner or operator of a source subject to the limitations of Section 218.204(l) of this Subpart shall use conventional air spray guns to apply coating materials to wood furniture under the circumstances specified in subsections (b)(1) through (4) of this Section:
c) Cleaning and storage requirements. Each owner or operator of a source subject to the limitations of Section 218.204(l) or (p) of this Subpart shall:
d) Additional cleaning and storage requirements for flat wood paneling coating lines. Every owner or operator of a source subject to the limitations of Section 218.204(p) of this Subpart shall: