a) The owner or operator of a petroleum solvent dry cleaning dryer shall either:
1)
Limit emissions of volatile organic material to the atmosphere to an average of
3.5 kilograms of volatile organic material per 100 kilograms dry weight of
articles dry cleaned, or
2) Install
and operate a solvent recovery dryer in a manner such that the dryer remains
closed and the recovery phase continues until a final solvent flow rate of 50
milliliters per minute is attained.
b) The owner or operator of a petroleum solvent filtration system shall either:
1)
Reduce the volatile organic material content in all filtration wastes to 1.0
kilogram or less per 100 kilograms dry weight of articles dry cleaned, before
disposal, and exposure to the atmosphere, or
2) Install and operate a cartridge filtration
system, and drain the filter cartridges in their sealed housings for 8 hours or
more before their removal.
Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.