Section 215.183 - Open Top Vapor Degreasing
Universal Citation: 35 IL Admin Code ยง 215.183
Current through Register Vol. 48, No. 38, September 20, 2024
a) Operating Requirements: No person shall operate an open top vapor degreaser unless:
1) The cover of the degreaser is
closed when workloads are not being processed through the degreaser;
2) Solvent carryout emissions are minimized
by:
A) Racking parts to allow complete
drainage;
B) Moving parts in and
out of the degreaser at less than 3.3 m/min (11 ft/min);
C) Holding the parts in the vapor zone until
condensation ceases;
D) Tipping out
any pools of solvent on the cleaned parts before removal from the vapor zone;
and,
E) Allowing parts to dry
within the degreaser until visually dry.
3) Porous or absorbent materials, such as
cloth, leather, wood or rope are not degreased;
4) Less than half of the degreaser's open top
area is occupied with a workload;
5) The degreaser is not loaded to the point
where the vapor level would drop more than 10 cm (4 in) when the workload is
removed from the vapor zone;
6)
Spraying is done below the vapor level only;
7) Solvent leaks are repaired
immediately;
8) Waste solvent is
stored in covered containers only and not disposed of in such a manner that
more than 20% of the waste solvent (by weight) is allowed to evaporate into the
atmosphere;
9) Water is not
visually detectable in solvent exiting from the water separator; and
10) Exhaust ventilation exceeding 20 cubic
meters per minute per square meter (65 cubic feet per minute per square foot)
of degreaser open area is not used, unless necessary to meet the requirements
of the Occupational Safety and Health Act ( 29 U.S.C. Section 651 et
seq.)
b) Equipment Requirements: No person shall operate an open top vapor degreaser unless:
1) The degreaser is equipped with a cover
designed to open and close easily without disturbing the vapor zone;
2) The degreaser is equipped with the
following switches:
A) A device which shuts
off the sump heat source if the amount of condenser coolant is not sufficient
to maintain the designed vapor level; and
B) A device which shuts off the spray pump if
the vapor level drops more than 10 cm (4 in) below the bottom condenser coil;
and
C) A device which shuts off the
sump heat source when the vapor level exceeds the design level.
3) A permanent conspicuous label
summarizing the operating procedure is affixed to the degreaser;
4) The degreaser is equipped with one of the
following devices:
A) A freeboard height of
3/4 of the inside width of the degreaser tank or 91 cm (36 in), whichever is
less; and if the degreaser opening is greater than 1 square meter (10.8 square
feet), a powered or mechanically assisted cover; or
B) Any other equipment or system of
equivalent emission control as approved by the Agency. Such equipment or system
may include a refrigerated chiller, an enclosed design or a carbon adsorption
system.
Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.