Illinois Administrative Code
Title 32 - ENERGY
Part 351 - RADIATION SAFETY REQUIREMENTS FOR WIRELINE SERVICE OPERATIONS AND SUBSURFACE TRACER STUDIES
Subpart C - EQUIPMENT
Section 351.410 - Design and Performance Criteria for Sources
Current through Register Vol. 48, No. 12, March 22, 2024
a) A licensee may not use a sealed source in well logging unless:
b) For a sealed source manufactured on or before July 14, 1989, a licensee may use the sealed source in well logging applications only if it meets the requirements of the United States of America Standards Institute (USASI) N5.10 -1968, "Classification of Sealed Radioactive Sources", incorporated by reference in Section 351.25, or the requirements in subsection (c) or (d).
c) For a sealed source manufactured after July 14, 1989, a licensee may use the sealed source in well logging applications if it meets the oil well logging requirements of the American National Standards Institute/Health Physics Society (ANSI/HPS) N43.6 -1997, "Sealed Radioactive Sources - Classification."
d) For a sealed source manufactured after July 14, 1989, a licensee may use the sealed source, for well logging applications only if a prototype of the sealed source has been tested and found to maintain its integrity after each of the following tests:
e) The requirements of subsections (a), (b), (c), and (d) do not apply to sealed sources that contain licensed material in gaseous form.
f) The requirements of subsections (a), (b), (c), and (d) do not apply to energy compensation sources (ECSs). ECSs shall be registered with the Agency, the U.S. Nuclear Regulatory Commission, or another Agreement State pursuant to the equivalent of 32 Ill. Adm. Code 330.280(m)(2) and 10 CFR 32.210.