Illinois Administrative Code
Title 32 - ENERGY
Part 350 - RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS
Subpart B - EQUIPMENT CONTROL
Section 350.1090 - Permanent Radiographic Installations

Current through Register Vol. 48, No. 12, March 22, 2024

Permanent radiographic installations using radiographic exposure device(s) having high radiation area entrance controls of the type described in 32 Ill. Adm. Code 340.610(a)(2), 340.610(a)(3) and 340.610(b) shall also meet the following requirements:

a) Each entrance that is used for personnel access to the high radiation area shall have both visible and audible warning signals to warn of the presence of radiation. The visible signal shall be activated by radiation. The audible signal shall be activated when an attempt is made to enter the installation while the source is exposed.

b) The entrance control device or alarm system shall be tested for proper operation prior to beginning operations on each day of use. The radiography system shall not be used if any entrance control device or alarm system is operating improperly. If an entrance control device or alarm system is operating improperly, it shall be labeled as defective immediately and repaired. Before the radiography system is returned to service, the radiation safety officer shall retest the entrance control device or alarm system and approve the repair.

c) Records of tests performed pursuant to subsection (b) of this Section shall be maintained for inspection by the Agency for 5 years.

Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.