a) The licensee shall perform inspection and maintenance checks that include, at a minimum, each of the following at the frequency specified in the license or license application:
1) Operability of each
aspect of the access control system required by Section
346.230 of this
Part.
2) Functioning of the source
position indicator required by Section
346.310(b)
of this Part.
3) Operability of the
radiation monitor for radioactive contamination in pool water required by
Section
346.590(b)
of this Part using a radiation check source, if applicable.
4) Operability of the over-pool radiation
monitor at underwater irradiators as required by Section
346.290(b)
of this Part.
5) Operability of the
product exit monitor required by Section
346.290(a)
of this Part.
6) Operability of the
emergency source return control required by Section
346.310(c)
of this Part.
7) Leak-tightness of
systems through which pool water circulates (visual inspection).
8) Operability of heat and smoke detectors
and extinguisher systems required by Section
346.270 of this
Part (but without turning extinguishers on).
9) Operability of the mean of pool water
replenishment required by Section
346.330(c)
of this Part.
10) Operability of
the indicators of high and low pool water levels required by Section
346.330(d)
of this Part.
11) Operability of
the intrusion alarm required by Section
346.230(i)
of this Part, if applicable.
12)
Functioning and wear of the system, mechanisms and cables used to raise and
lower sources.
13) Condition of the
barrier to prevent products from hitting the sources or source mechanism as
required by Section
346.350 of
this Part.
14) Amount of water
added to the pool to determine if the pool is leaking.
15) Electrical wiring on required safety
systems for radiation damage.
16)
Pool water conductivity measurements and analysis as required by Section
346.630(b)
of this Part.
b) Malfunctions and defects found during inspection and maintenance checks shall be repaired without undue delay.
Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.