Illinois Administrative Code
Title 32 - ENERGY
Part 346 - LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS
Subpart C - DESIGN AND PERFORMANCE REQUIREMENTS OF IRRADIATORS
Section 346.290 - Radiation Monitors

Current through Register Vol. 48, No. 12, March 22, 2024

a) Irradiators with automatic product conveyor systems shall have a radiation monitor with an audible alarm located to detect loose radioactive sources that are carried toward the product exit. If the monitor detects a source, an alarm shall sound and product conveyors shall stop automatically and the sources shall become fully shielded. The alarm shall be capable of alerting personnel in the facility who are prepared to summon assistance. Underwater irradiators in which the product moves within an enclosed stationary tube are exempt from the requirements of this subsection.

b) Underwater irradiators that are not in a shielded radiation room shall have a radiation monitor over the pool to detect abnormal radiation levels. The monitor shall have an audible alarm and a visible indicator at entrances to the personnel access barrier around the pool. The audible alarm may have a manual shut-off. The alarm shall be capable of alerting personnel who are prepared to respond promptly.

Disclaimer: These regulations may not be the most recent version. Illinois may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.