Table A - MPE for Ocular Exposure (Intrabeam Viewing)
Ultraviolet
Wavelength (µ m) |
Exposure Duration, ts |
(J cm-2) |
MPE (W cm-2) |
0.180 to 0.302 |
10-9 to 3 x 104 |
3 x 10-3 |
|
0.303 |
10-9 to 3 x 104 |
4 x 10-3 |
|
0.304 |
10-9 to 3 x 104 |
6 x 10-3 |
|
0.305 |
10-9 to 3 x 104 |
10 x 10-3 |
|
0.306 |
10-9 to 3 x 104 |
16 x 10-3 |
|
0.307 |
10-9 to 3 x 104 |
25 x 10-3 |
|
0.308 |
10-9 to 3 x 104 |
40 x 10-3 |
|
0.309 |
10-9 to 3 x 104 |
63 x 10-3 |
|
0.310 |
10-9 to 3 x 104 |
0.1 |
|
0.311 |
10-9 to 3 x 104 |
0.16 |
|
0.312 |
10-9 to 3 x 104 |
0.25 |
|
0.313 |
10-9 to 3 x 104 |
0.40 |
|
0.314 |
10-9 to 3 x 104 |
0.63 |
|
0.315 to 0.400 |
10-9 to 10 |
0.56 t1/4 |
|
0.315 to 0.400 |
10 x 3 x 104 |
1.0 |
NOTE: To calculate MPE, use the J cm-2 value shown or 0.56t¼, whichever is lower.
Visible and Near Infrared
Wavelength (µ m) |
Exposure Duration, ts |
(J cm-2) |
MPE (W cm-2) |
0.400 to 0.700 |
10-9 to 18 x 10-6 |
0.5 x 10-6 |
|
0.400 to 0.700 |
18 x 10-6 to 10 |
1.8 t3/4 x 10-3 |
|
0.400 to 0.550 |
10 to 104 |
10 x 10-3 |
|
0.550 to 0.700 |
10 to T1 |
1.8 t3/4 x 10-3 |
|
0.550 to 0.700 |
T1 to 104 |
10CB to 10-3 |
|
0.400 to 0.700 |
104 to 3 x 104 |
CB x 10-6 |
|
0.700 to 1.050 |
10-9 to 18 x 10-6 |
0.5CA x 10-6 |
|
0.700 to 1.050 |
18 x 10-6 to 103 |
1.8CAt3/4 x 10-3 |
|
0.700 to 1.050 |
103 to 3 x 104 |
320CA x 10-6 |
|
1.050 to 1.400 |
10-9 to 50 x 10-6 |
5Cc x 10-6 |
|
1.050 to 1.400 |
50 x 10-6 to 103 |
9.0 Cct3/4 x 10-3 |
|
1.050 to 1.400 |
103 to 3 x 104 |
1.6 Cc x 10-3 |
NOTES: |
1. |
See Section 315.Tables D & E for limiting apertures (see ANSI Z136.1 pg. 44). |
2. |
For multiple pulses, apply correction factor Cp given in Section 315.Table C. |
|
3. |
For information on correction factors T1, CB, CA, Cp and Cc, see Section 315.Table C. |
Far Infrared
Wavelength (µ m) |
Exposure Duration, ts |
(J cm-2) |
MPE (W cm-2) |
1.400 to 1.500 |
10-9 to 10-3 |
0.1 |
|
1.400 to 1.500 |
10-3 to 10 |
0.56t1/4 |
|
1.400 to 1.500 |
10 to 3 x 104 |
0.1 |
|
1.500 to 1.800 |
10-9 to 10 |
1.0 |
|
1.500 to 1.800 |
10 to 3 x 104 |
0.1 |
|
1.800 to 2.600 |
10-9 to 10-3 |
0.1 |
|
1.800 to 2.600 |
10-3 to 10 |
0.56t1/4 |
|
1.800 to 2.600 |
10 to 3 x 104 |
0.1 |
|
2.600 to 103 |
10-9 to 10-7 |
10 x 10-3 |
|
2.600 to 103 |
10-7 to 10 |
0.56t1/4 |
|
2.600 to 103 |
10 to 3 x 104 |
0.1 |
NOTES: |
1. |
See Section 315.Tables D & E for limiting apertures (see ANSI Z136.1 pg. 44). |
|||
2. |
For multiple pulses, apply correction factor Cp given in Section 315.Table C. |
GENERAL NOTES: |
1. |
The MPE for diffuse reflections at wave lengths between 0.400 and 1.400µm is obtained by multiplying the corresponding MPEs above by CE (see Section 315.Table C for correction factors and T1). |
|||
2. |
For repeated (pulsed) exposures, see ANSI Z136.1. |
||||
3. |
For purposes of this Section 315.Table A, the following abbreviations or symbols are used: |
||||
µm |
= |
micrometers |
|||
ts |
= |
time in seconds |
|||
J |
= |
joules |
|||
W |
= |
watts |
|||
cm |
= |
centimeters |