Idaho Administrative Code
Title IDAPA 24 - Occupational and Professional Licenses, Division of
Rule 24.39.80 - IDAHO MINIMUM SAFETY STANDARDS AND PRACTICES FOR LOGGING
Subchapter I - CANOPY AND CANOPY CONSTRUCTION FOR LOGGING EQUIPMENT
Section 24.39.80.401 - GENERAL REQUIREMENTS

Universal Citation: ID Admin Code 24.39.80.401

Current through September 2, 2024

01. Driver Protection Guard.

a. A substantial metal guard for the protection of the driver shall be installed on every piece of equipment, where exposed to overhead hazards.

b. This guard shall be strongly constructed to afford adequate protection for the driver against overhead hazards.

c. This guard shall be of sufficient width and height so that it will not impair the movements of the driver or prevent his immediate escape from the equipment in emergencies.

d. This guard shall be of open construction to allow the driver all the visibility possible.

02. Canopy Framework.

a. The canopy framework shall consist of at least two (2) arches, either transverse or longitudinal.

b. If transverse, one (1) arch shall be installed at the rear of the equipment and the other at the center of the equipment. They shall be joined together by three (3) longitudinal braces, one (1) at the top and one (1) at each side of the arches.

c. There shall be a shear or deflecting guard extending from the leading edge of the forward arch to the front part of the frame of the tractor or similar equipment.

d. If longitudinal arches are used, they shall be extended from the rear of the tractor or equipment to the front frame of the tractor or equipment and each arch shall have an intermediate support located approximately at the dash so that ingress or egress will not be impeded.

e. Regardless of the type of construction used, the fabrication and method of connecting to the tractor or equipment shall be of such design as to develop a strength equivalent to that of the upright members.

03. Canopy Structure. The canopy structural framework shall be fabricated of pipe of the following size, or materials of equivalent strength, depending upon the gross weight of the tractor or similar equipment as equipped. Under twenty-eight thousand (28,000) lbs., two (2) inch double extra strong pipe (XXS); twenty-eight thousand (28,000) to fifty-eight thousand (58,000) lbs., three (3) inch double extra strong pipe (XXS); over fifty-eight thousand (58,000) lbs., four (4) inch double extra strong pipe (XXS).

04. Gusset Plates or Braces. Gusset plates or braces shall be installed on the canopy framework so that the framework will withstand a horizontal pressure equal to twenty-five percent (25%) of the gross weight of the tractor or similar equipment, as equipped, when such pressure is applied to any vertical member at a point not more than six (6) inches below the roof of the canopy.

05. Clearance Above the Deck. The clearance above the deck of the tractor or similar equipment at points of egress shall be not less than fifty-two (52) inches and the clearance above the driver's seat shall be of such height as will allow sufficient clearance above the driver's head.

06. Overhead Covering. The overhead covering on the canopy structure shall be of not less than three-sixteenth (3/16) inch steel plate except that the forward eighteen (18) inches may be made of one quarter (1/4) inch woven wire having not more than one (1) inch mesh.

07. Rear Covering.

a. The opening in the rear of the structure shall be covered with one quarter (1/4) inch woven wire having not less than one and one half (1 1/2) inch or more than two (2) inch wire mesh. This covering shall be affixed to the structural members so that ample clearance will be provided between the screen and the back of the operator.

b. Structural members shall present smooth, rounded edges and the covering shall be free from projections which would tend to puncture or tear flesh or clothing.

08. Pin Connections.

a. Pin connections are recommended for joints in the structural frame and especially at connections to the tractor frame or similar equipment frame.

b. Gusset plates shall be installed at each place where individual pieces of pipe are joined.

09. Sideguards. When practical, sideguards shall be installed to protect the operator from hazards.

Effective March 31, 2022

Disclaimer: These regulations may not be the most recent version. Idaho may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.