Idaho Administrative Code
Title IDAPA 16 - Health and Welfare, Department of
Rule 16.02.14 - CONSTRUCTION AND OPERATION OF PUBLIC SWIMMING POOLS
Section 16.02.14.281 - OVERFLOW GUTTERS
Universal Citation: ID Admin Code 16.02.14.281
Current through September 2, 2024
The gutter, drains, and return piping to the surge system must be designed to rapidly remove overflow water caused by recirculation displacement, wave action, or other causes produced from the maximum pool bathing load.
01. General Requirements. Overflow gutters must:
a. Extend around the entire perimeter of the pool except at steps or recessed ladders;
b. Have the gutter lip be level within three-tenths (.3) inch;
c. Be capable of continuously removing fifty percent (50%) of the recirculated water and returning it to the recirculation system; and
d. Be designed to prevent entrance or entrapment of bathers.
02. Overflow Gutters Connected to the Recirculation System. All overflow gutters connected to the recirculation system must be connected in an approved manner, such as a surge tank.
Effective March 15, 2022
Disclaimer: These regulations may not be the most recent version. Idaho may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.