Idaho Administrative Code
Title IDAPA 16 - Health and Welfare, Department of
Rule 16.02.14 - CONSTRUCTION AND OPERATION OF PUBLIC SWIMMING POOLS
Section 16.02.14.251 - RECIRCULATION SYSTEM: SIZING
Universal Citation: ID Admin Code 16.02.14.251
Current through September 2, 2024
All equipment and connecting piping must be designed to reduce friction losses, and for the piping to carry the required quantity of water at a velocity not to exceed six (6) feet per second for suction side pipe, and not more than ten (10) feet per second for filter discharge pipe. Piping must be of non-toxic material, resistant to corrosion, and able to withstand normal operating pressures. It is recommended all plastic pipes conform with NSF Standard 14 for potable water applications of the National Sanitation Foundation (NSF) and bear the NSF seal.
Effective March 15, 2022
Disclaimer: These regulations may not be the most recent version. Idaho may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.