Hawaii Administrative Rules
Title 6 - DEPARTMENT OF BUDGET AND FINANCE
Division - PUBLIC UTILITIES COMMISSION
Chapter 77 - TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE; MINIMUM SAFETY STANDARDS
Subchapter 14 - OPERATIONS
Section 6-77-160 - Change in class location: required study

Universal Citation: HI Admin Rules 6-77-160

Current through August, 2024

Whenever an increase in population density indicates a change in class location for a segment of an existing steel pipeline operating at hoop stress that is more than forty percent of SMYS; or indicates that the hoop stress corresponding to the established maximum allowable operating pressure for a segment of existing pipeline is not commensurate with the present class location, the operator shall immediately make a study to determine:

(1) The present class location for the segment involved;

(2) The design, construction, and testing procedures followed in the original construction, and a comparison of these procedures with those required for the present class location by the applicable provisions of this chapter;

(3) The physical condition of the segment of the extent it can be ascertained from available records;

(4) The operating and maintenance history of the segment;

(5) The maximum actual operating pressure and the corresponding hoop stress, taking pressure gradient into account, for the segment of pipeline involved; and

(6) The actual area affected by the population density increase, and physical barriers or other factors which may limit further expansion of the more densely populated area.

Disclaimer: These regulations may not be the most recent version. Hawaii may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.