Hawaii Administrative Rules
Title 6 - DEPARTMENT OF BUDGET AND FINANCE
Division - PUBLIC UTILITIES COMMISSION
Chapter 77 - TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE; MINIMUM SAFETY STANDARDS
Subchapter 10 - CUSTOMER METERS, SERVICE REGULATORS, AND SERVICE LINES
Section 6-77-112 - Service lines: valve requirements
Current through August, 2024
(a) Each service line must have a service-line valve that meets the applicable requirements of subchapters 4 and 6. A valve incorporated in a meter bar, that allows the meter to be bypassed, may not be used as a service line valve.
(b) A soft seat service line valve may not be used if its ability to control the flow of gas could be adversely affected by exposure to anticipated heat.
(c) Each service-line valve on a high-pressure service line, installed above ground or in an area where the blowing of gas would be hazardous, must be designed and constructed to minimize the possibility of the removal of the core of the valve with other than specialized tools.