Hawaii Administrative Rules
Title 3 - DEPARTMENT OF ACCOUNTING AND GENERAL SERVICES
Building Code Council
State Energy Conservation Code
Subchapter 2 - AMENDMENTS TO THE 2018 ICC INTERNATIONAL ENERGY CONSERVATION CODE
23 - Mass walls
Universal Citation: HI Admin Rules 23
Current through August, 2024
IECC Section R402.2.5 Mass walls is amended to read as follows:
1. Above-ground walls of concrete block, (concrete masonry units) CMU, concrete, insulated concrete form, masonry cavity, brick but not brick veneer, adobe, compressed earth block, rammed earth, solid timber or solid logs.
2. Any wall having a heat capacity greater than or equal to 6 Btu/ft2·°F (123 kJ/m2·K).
3. Concrete, CMU and similar mass walls are 6 inches or greater in thickness.
Disclaimer: These regulations may not be the most recent version. Hawaii may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.