Hawaii Administrative Rules
Title 3 - DEPARTMENT OF ACCOUNTING AND GENERAL SERVICES
Building Code Council
State Energy Conservation Code
Subchapter 2 - AMENDMENTS TO THE 2018 ICC INTERNATIONAL ENERGY CONSERVATION CODE
21 - INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTS
Universal Citation: HI Admin Rules 21
Current through January, 2025
IECC Table R402.1.2 is amended to read as follows:
Climate Zone 1
Mass Wall R-Value: 3/4 or NRj.
j Exception: R-value for mass walls are not required if mass walls meet one of the following requirements:
1. have a reflectance =0.64.
2. have overhangs with a projection factor =0.3.
3. are =6 inches in thickness.
Disclaimer: These regulations may not be the most recent version. Hawaii may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.