IECC Table R402.1.2 is added to the table:
Window SHGC Requirements
Projection Factor of overhang from base of average window sill |
SHGC |
.25 |
|
<30 - .50 |
.40 |
[GREATER THAN OR EQUAL TO].50 |
N/A |
Exception: North-facing windows with pf [GREATER THAN] .20 are exempt from the SHGC requirement. Overhangs shall extend 2 feet on each side of window or to nearest wall, whichever is less.
Disclaimer: These regulations may not be the most recent version. Hawaii may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.