Elevator doors shall open and close automatically. They shall be provided with a reopening device that will stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an object or person. The device shall be capable of completing these operations without requiring contact for an obstruction passing through the opening at heights of five (5)inches and twenty-nine (29) inches or 125 and 735 millimeters, respectively, from the floor as shown in Figure 240-1, titled, "Hoistway and Elevator Entrances", dated December 6, 1990, which is made a part of this chapter, and located at the end of this chapter. Door reopening devices shall remain effective for at least twenty (20) seconds. After such an interval, doors may close in accordance with the requirements of ANSI A17.1b-1989.

Disclaimer: These regulations may not be the most recent version. Hawaii may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.