Hawaii Administrative Rules
Title 12 - DEPARTMENT OF LABOR AND INDUSTRIAL RELATIONS
Subtitle 8 - HAWAII OCCUPATIONAL SAFETY AND HEALTH DIVISION
Part 11 - ELEVATORS AND RELATED SYSTEMS
Chapter 229 - GENERAL, ADMINISTRATIVE, AND LEGAL PROVISIONS
Exhibit C - INSPECTION AND TEST INTERVALS (IN MONTHS)

Universal Citation: HI Admin Rules C
Current through August, 2024

Equipment Type

Permit Renewal

Category 3

Category 5

Electrical Elevators

12

N/A

60

Hydraulic Elevators

12

36

N/A

Escalators and Moving Walks[1]

12

36

N/A

Dumbwaiters

12

36

60

Material Lifts

12

36

60

Platform Lifts and Stairway Chairlifts

12

N/A

N/A

Inclined Elevators

12

36

60

Screw-Column Elevators

12

36

60

Roof-top Elevators

12

36

60

Limited-use/Limited-Application Elevators

3

36

60

Construction Cars

3

36

60

Personnel Hoists[2]

3

N/A

N/A

Amusement Rides

6

N/A

N/A

1 Internal inspections of escalators and moving walks shall be performed at intervals of 36 months.

2 Personnel hoists shall be load tested at intervals of 3 months.

Where an equipment is listed under both Category 3 of 36 months and Category 5 of 60 months, the appropriate testing interval is dependent on whether the lifting mechanism is rope or hydraulic or a combination of rope and hydraulic.

Disclaimer: These regulations may not be the most recent version. Hawaii may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.