Rule 511-3-6-.08 - Appendix

Current through Rules and Regulations filed through September 23, 2024

Table 1: Minimum Number of Portable Sanitation Units at Construction Sites

Number of Workers*

Minimum Number of Units

Serviced Weekly**

20 or less ..

1 Toilet per 20 Workers

21 or more ..

1 Additional Toilet per 40 Workers

200 or more ..

1 Additional Toilet per 50 Workers

29 CFR 1926.51 OSHA Regulations for Toilets at Construction Sites

* The number of portable sanitation units required shall be determined by the maximum number of workers present on a regular 8 hour shift. Shifts lasting longer than 8 hours (40 hour work week) should double the number of portable sanitation units.

** "Servicing" refers to the emptying of waste and the cleaning of the portable sanitation unit.

Table 2. Portable Sanitation Units for Special Events Planning

AVERAGE

CROWD

SIZE

AVERAGE HOURS AT THE EVENT *

1 2 3 4 5 6 7 8 9 10

500

2 4 4 5 6 7 9 9 10 12

1,000

4 6 8 8 9 9 11 12 13 13

2,000

5 6 9 12 14 16 18 20 23 25

3,000

6 9 12 16 20 24 26 30 34 38

4,000

8 13 16 22 25 30 35 40 45 50

5,000

12 15 20 25 31 38 44 50 56 63

10,000

15 25 38 50 63 75 88 100 113 125

15,000

20 38 56 75 94 113 131 150 169 188

20,000

25 50 75 100 125 150 175 200 225 250

25,000

38 69 99 130 160 191 221 252 282 313

30,000

46 82 119 156 192 229 266 302 339 376

35,000

53 96 139 181 224 267 310 352 395 438

40,000

61 109 158 207 256 305 354 403 452 501

45,000

68 123 178 233 288 343 398 453 508 563

50,000

76 137 198 259 320 381 442 503 564 626

55,000

83 150 217 285 352 419 486 554 621 688

60,000

91 164 237 311 384 457 531 604 677 751

65,000

98 177 257 336 416 495 575 654 734 813

70,000

106 191 277 362 448 533 619 704 790 876

75,000

113 205 296 388 480 571 663 755 846 938

80,000

121 218 316 414 512 609 707 805 903 1001

85,000

128 232 336 440 544 647 751 855 959 1063

90,000

136 246 356 466 576 686 796 906 1016 1126

95,000

143 259 375 491 607 724 840 956 1072 1188

100,000

151 273 395 517 639 762 884 1006 1128 1251

Based on "Portable Restroom Requirements at Special Events and Crowd Gatherings" Center for Business and Industrial Studies, University of Missouri-St. Louis

* Determine the appropriate potable sanitation units needed form the table above.

* For each sewered toilet available onsite, subtract 1 from the previously calculated number.

* If alcoholic beverages are to be served, add 25% to the base number.

* For peak crowd numbers that fall between chart numbers, round up to the next base number.

* Units shall be provided in accordance with the Georgia Accessibility Code following

state or local requirements.

* Table based on units being serviced daily

O.C.G.A. Sections 31-2A-6, 31-12-8, 31-27-9, 12-8-1.

Disclaimer: These regulations may not be the most recent version. Georgia may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.