Compilation of Rules and Regulations of the State of Georgia
Department 391 - RULES OF GEORGIA DEPARTMENT OF NATURAL RESOURCES
Chapter 391-3 - ENVIRONMENTAL PROTECTION
Subject 391-3-24 - LEAD-BASED PAINT HAZARD MANAGEMENT
Rule 391-3-24-.07 - Lead Clearance Levels

Current through Rules and Regulations filed through September 23, 2024

Clearance procedures shall be conducted on all abatement projects by a certified inspector or lead risk assessor after appropriate cleaning has been completed. The following lead clearance levels must be met.

CLEARANCE DUST STANDARDS (Wipe Sampling Only)

Surface/ Medium

Level (µg/ft2)

(Equal to or less than)

Bare and carpeted floors

10 µg/ft2

Interior Window Sills

100 µg/ft2

Window Troughs

400 µg/ft2

Exterior Concrete

800 µg/ft2

O.C.G.A. § 31-41-1, et seq.

Disclaimer: These regulations may not be the most recent version. Georgia may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.