Florida Administrative Code
64 - DEPARTMENT OF HEALTH
64E - Division of Environmental Health
Chapter 64E-5 - CONTROL OF RADIATION HAZARDS
Section 64E-5.1421 - Inspection and Maintenance
Universal Citation: FL Admin Code R 64E-5.1421
Current through Reg. 50, No. 187; September 24, 2024
(1) The licensee shall perform inspection and maintenance checks that include, as a minimum, each of the following at the frequency specified in the license or license application:
(a) Operation of each aspect of
the access control system required by Rule
64E-5.1406, F.A.C.;
(b) Functioning of the source position
indicator required by subsection
64E-5.1410(2),
F.A.C.;
(c) Operation of the
radiation monitor on the pool water purification system using a radioactive
check source to detect radioactive contamination in pool water as required by
subsection 64E-5.1409(2),
F.A.C.;
(d) Operation of the
over-pool radiation monitor at underwater irradiators as required by subsection
64E-5.1409(3),
F.A.C.;
(e) Operation of the
product exit monitor required by subsection
64E-5.1409(1),
F.A.C.;
(f) Operation of the
emergency source return control required by subsection
64E-5.1410(3),
F.A.C.;
(g) Leak-tightness of
systems through which pool water circulates (visual inspection);
(h) Operation of the heat and smoke detectors
and extinguisher system required by Rule
64E-5.1408, F.A.C., but without
turning on extinguishers;
(i)
Operation of the means of pool water replenishment required by subsection
64E-5.1411(3),
F.A.C.;
(j) Operation of the
visible indicator of low and high pool water level required by subsection
64E-5.1411(4),
F.A.C.;
(k) Operation of the
intrusion alarm required by subsection
64E-5.1406(2),
F.A.C.;
(l) Functioning and wear on
the system, mechanisms, and cables used to raise and lower sources;
(m) Condition of the barrier to prevent
products from hitting the sources or source mechanism and the operation of the
collision alarm system, as required by Rule
64E-5.1412, F.A.C.;
(n) Amount of water added to the pool to
determine if the pool is leaking;
(o) Electrical wiring on required safety
systems for radiation damage;
(p)
Pool water conductivity measurements and analysis as required by Rule
64E-5.1422, F.A.C.;
(q) Condition of the product carriers;
and,
(r) Operation of the siphon
breakers in the pool plumbing.
(2) Malfunction and defects found during inspection and maintenance checks must be repaired without undue delay.
Rulemaking Authority 404.051(4) FS. Law Implemented 404.051(1), (5), (6), 404.061, 404.081, 404.141 FS.
New 8-14-96, Formerly 10D-91.1521.
Disclaimer: These regulations may not be the most recent version. Florida may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.