Florida Administrative Code
5 - DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES
5E - Division of Agricultural Environmental Services
Chapter 5E-14 - ENTOMOLOGY - PEST CONTROL REGULATIONS
Part I - PUBLIC HEALTH AND SAFETY
Section 5E-14.112 - Fumigation Requirements - Prefumigation Inspections, Evacuation, Warning Notices (Signs), Special Safety Precautions and Responsibilities
Current through Reg. 50, No. 187; September 24, 2024
(1) Final pre-application of fumigant and evacuation inspection: Before the fumigant(s) is to be applied, the certified operator in charge or his designated special fumigation identification card holder must make a final, personal inspection of the structure and shall ensure that:
On multi-unit dwellings, the certified fumigation operator in charge and/or his designated special fumigation identification cardholder shall conduct a thorough, systematic inspection of each room in every unit to ensure that all provisions specified above have been completed. Then, exterior doors and/or entrances of each inspected unit shall be secured against unauthorized re-entry while preparations and inspection of other units or areas of the structure are completed. This may require the temporary use of secondary locks on entrances that are to be left unattended between the time of inspection and the introduction of the fumigant. If an individual unit or units cannot be safely secured while preparations of other areas are taking place, then those units must be re-inspected immediately before the fumigant is to be applied.
(2) Prior to the application of fumigant(s), suitable warning signs of stiff, weather-proof material must be securely affixed and conspicuously posted as follows:
(3) Warning signs shall conform in design and information set forth as follows:
(Skull and Crossbones Symbol) |
Danger |
(Skull and Crossbones Symbol) |
Fumigating with |
||
(Accepted common name of Fumigant) |
||
Deadly Poison |
||
All Persons are Warned to Keep Away |
Date and time fumigant was introduced ___
Company Name ___
Company Business Address ___
Certified Operator in Charge ___
Fumigant Introduced by ___
Day Telephone ______
Night Telephone ______
(4) Signs required must be printed, painted or made in indelible red ink or paint insoluble in water, on white background. The words "Danger" and "Deadly Poison" shall be in block lettering at least two (2'') inches high. The name of the fumigant shall be at least five-eighths (5/8'') inch high. The skull and crossbones symbol shall be at least one (1'') inch high. All other lettering on the sign must be not less than one-half (1/2'') inch high.
(5) All information displayed on warning signs must be accurate and legible. The name and day and night telephone number of the certified operator in charge of fumigation, or a certified fumigation operator, or a special fumigation identification cardholder who introduced the fumigant at the fumigation site must be displayed on the warning sign. Additional numbers and other contact information may be placed on the sign. All emergency phone numbers must be a phone number, mobile/cell phone number or beeper number in the possession of a person familiar with the job and trained to respond to fumigation emergencies and equipped with label required respiratory protection and gas detection equipment. Answering machines, beepers or voice mail systems that do not provide a mechanism for immediate notification to an individual as described above are prohibited. A 24 hour manned answering service that can immediately contact a certified fumigation operator or a special fumigation identification cardholder of the company who can respond to the emergency is acceptable.
(6) Such warning signs posted on the outside of tents or sealing covers shall not be removed prior to commencement of ventilation: and such warning signs posted on or at entrances to the structure (itself), enclosed space or commodities being fumigated shall not be removed until the end of the fumigation period, when ventilation has been completed and the premises declared safe for reoccupancy as required by subsections 5E-14.113(1) and (2), F.A.C. Ventilation shall be conducted with due regard for the public safety.
(7) Special safety precautions, responsibilities.
Rulemaking Authority 482.051 FS. Law Implemented 482.051(1), 482.152 FS.