Section 15C-1.0106 - Pier Specifications

Universal Citation: FL Admin Code R 15C-1.0106

Current through Reg. 50, No. 249, December 24, 2024

(1) Each pier shall be required to withstand 2500 pounds plus a 2.5 safety factor from a vertical projection and from a horizontal projection equal to the same angle or degree of angle of the leg or support, using the same weight and safety factor. Three (3) consecutive tests must be performed without a failure. (Horizontal projection test not required on piers of less than twelve inches (12'') in height including adjustment.)

(2) Piers manufactured with adjustable heights shall be tested at maximum heights. Test results shall be reported in the format shown in Example No. I.

Click here to view image

Rulemaking Authority 320.011, 320.824(1), 320.8325(1) FS. Law Implemented 320.77(10), 320.822(12), 320.8285, 320.8325, 320.835(2) FS.

New 1-10-94, Amended 10-2-95.

Disclaimer: These regulations may not be the most recent version. Florida may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.