Appendix 6 CCR 1007-1-6-G - AUTOMATIC FILM PROCESSOR TECHNIQUE CHART

Current through Register Vol. 48, No. 6, March 25, 2025

Developer Temperature

Minimum Immersion Timea/

°C 35.5

°F 96

Seconds 19

35

95

20

34.5

94

21

34

93

22

33.5

92

23

33

91

24

32

90

25

31.5

89

26

31

88

27

30.5

87

28

30

86

29

29.5

85

30

a/ Immersion time only, no crossover time included.

Disclaimer: These regulations may not be the most recent version. Colorado may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.