Code of Colorado Regulations
1000 - Department of Public Health and Environment
1007 - Hazardous Materials and Waste Management Division
6 CCR 1007-1 - RULES AND REGULATIONS PERTAINING TO THE ADMINISTRATION AND ENFORCEMENT OF THE PESTICIDE APPLICATORS' ACT
Part 04 - RADIATION CONTROL - STANDARDS FOR PROTECTION AGAINST RADIATION
OCCUPATIONAL DOSE LIMITS
Section 6 CCR 1007-1-4.9 - Determination of Internal Exposure
Current through Register Vol. 48, No. 11, June 10, 2025
4.9.1 For purposes of assessing dose used to determine compliance with occupational dose equivalent limits, the licensee or registrant shall, when required pursuant to 4.18, take suitable and timely measurements of:
4.9.2 Unless respiratory protective equipment is used, as provided in 4.24, or the assessment of intake is based on bioassays, the licensee or registrant shall assume that an individual inhales radioactive material at the airborne concentration in which the individual is present.
4.9.3 When specific information on the physical and biochemical properties of the radionuclides taken into the body or the behavior of the material in an individual is known, the licensee or registrant may:
4.9.4 If the licensee or registrant chooses to assess intakes of Class Y material using the measurements given in 4.9.1.2 or 4.9.1.3, the licensee or registrant may delay the recording and reporting of the assessments for periods up to 7 months, unless otherwise required by 4.52 or 4.53. This delay permits the licensee or registrant to make additional measurements basic to the assessments.
4.9.5 If the identity and concentration of each radionuclide in a mixture are known, the fraction of the DAC applicable to the mixture for use in calculating DAC-hours shall be either:
4.9.6 If the identity of each radionuclide in a mixture is known, but the concentration of one or more of the radionuclides in the mixture is not known, the DAC for the mixture shall be the most restrictive DAC of any radionuclide in the mixture.
4.9.7 When a mixture of radionuclides in air exists, a licensee or registrant may disregard certain radionuclides in the mixture if:
4.9.8 When determining the committed effective dose equivalent, the following information may be considered: