Code of Colorado Regulations
1000 - Department of Public Health and Environment
1007 - Hazardous Materials and Waste Management Division
6 CCR 1007-3 - HAZARDOUS WASTE
Part 264 - HAZARDOUS WASTE - STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE AND DISPOSAL FACILITIES
Subpart M - Land Treatment
Section 6 CCR 1007-3-264.273 - Design and Operating Requirements
Current through Register Vol. 47, No. 17, September 10, 2024
The Department will specify in the facility permit how the owner or operator will design, construct, operate, and maintain the land treatment in compliance with this section.
(a) The owner or operator must design, construct, operate, and maintain the unit to maximize the degradation, transformation, and immobilization of hazardous constituents in the treatment zone. The owner or operator must design, construct, operate, and maintain the unit in accord with all design and operating conditions that were used in the treatment demonstration under § 264.272. At a minimum, the Department will specify the following in the facility permit:
(b) The owner or operator must design, construct, operate, and maintain the treatment zone to minimize run-off of hazardous constituents during the active life of the land treatment unit.
(c) The owner or operator must design, construct, operate, and maintain a run-on control system capable of preventing flow onto the treatment zone during peak discharge from at least a 100-year storm.
(d) The owner or operator must design, construct, operate, and maintain a run off management system to collect and control at least the water volume resulting from a 24 hour, 100 year storm.
(e) Collection and holding facilities (e.g., tanks or basins) associated with run on and run off control systems must be emptied or otherwise managed expeditiously after storms to maintain the design capacity of the system.
(f) If the treatment zone contains particulate matter which may be subject to wind dispersal, the owner or operator must manage the unit to control wind dispersal.
(g) The owner or operator must inspect the unit weekly and after storms to detect evidence of: